Product Name: Screw-Down Metal Roof Anchor Part #: 00255 Instruction Manual Do not throw away these instructions! Read and understand these instructions before using equipment! Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Product Specific Applications 1-2 Limitations 2-3 Components and Specifications 3 Installation and Use 4-5 Maintenance, Cleaning, and Storage 5 Inspection 5 Inspection Log 6 Safety Information 6-7 Labels 7
Serial #: Trainer: User: Applicable Safety Standards When used according to instruction specifications, this product meets or exceeds all applicable OSHA 1926 Subpart M, OSHA 1910, ANSI Z359.1-2007, and ANSI A10.32-2012 standards for fall protection. Applicable standards and regulations depend on the type of work being done, and also might include state-specific regulations. Consult regulatory agencies for more information on personal fall arrest systems and associated components.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Restraint: Screw-Down Metal Roof Anchor may be used in Restraint applications. Restraint systems prevent workers from reaching the leading edge of a fall hazard. Always account for fully deployed length of lanyard/SRL. Structure must withstand loads applied in the directions permitted by the system of at least 1,000 lbs. No free fall is permitted.
Correct Anchorage Positioning: This chart details allowable working zones required to reduce risk of swing falls and improper side loading. ALWAYS adhere to information specified by chart.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Installation and Use Prior to installation, plan your system: 1. Fully inspect selected installation location and applicable work area as specified by this instruction manual. Eliminate all existing and potential hazards. Ensure selected installation location meets minimum strength requirements as specified by this instruction manual. 2.
If Screw-Down Metal Roof Anchor fails inspection in any way, immediately remove it from service, and contact Guardian to inquire about its return or repair. Cleaning after use is important for maintaining the safety and longevity of Screw-Down Metal Roof Anchor. Remove all dirt, corrosives, and contaminants from Screw-Down Metal Roof Anchor before and after each use. If Screw-Down Metal Roof Anchor cannot be cleaned with plain water, use mild soap and water, then rinse and wipe dry.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Inspection Log Date of First Use: __________________. Product lifetime is indefinite as long as it passes pre-use and Competent Person inspections. User must inspect prior to EACH use. Competent Person other than user must complete formal inspection at least every 6 months. Competent Person to inspect and initial. This inspection log must be specific to one Screw-Down Metal Roof Anchor.
Training of Authorized Persons to correctly erect, disassemble, inspect, maintain, store, and use equipment must be provided by a Competent Person. Training must include the ability to recognize fall hazards, minimize the likelihood of fall hazards, and the correct use of personal fall arrest systems. NEVER use fall protection equipment of any kind to hang, lift, support, or hoist tools or equipment, unless explicitly certified for such use.