Brochure

Table Of Contents
Technical data
UP Series
6
44
UP 15-18 BUC5/BUC7
Approvals
Note: Dimensions in inches unless otherwise noted.
TM03 8428 4412
0 1 2 3 4 5 6 7 8 9 10 11 12 13 Q [US GPM]
0
2
4
6
8
10
12
14
16
[ft]
H
0.0 0.5 1.0 1.5 2.0 2.5 3.0 Q [m³/h]
0
1
2
3
4
5
[m]
H
a. UP15-18BUC5
b. UP15-18BUC7
60 Hz
a
b
Flow range: 0-14.7 gpm (0-3.3 m
3
h)
Head range: 0-14.5 ft (4.4 m)
Motors: 2-pole, single-phase
Max. liquid temperature: 230 °F (110 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 145 psi (10 bar)
Model Volts Amps Watts Hp Capacitor
UP 15-18 BUC5 115 0.74 86 1/25 10 μF/180 V
UP 15-18 BUC7 115 0.74 86 1/25 10 μF/180 V
UP 15-18 BUC5 UP 15-18 BUC7
TM03 8549 1907
TM03 8753 2407
Model
Product
number
115 V
Dimensions [inches (mm)]
Connection type
and size
Shipping weight
[lbs (kg)]
ABC D EF
UP 15-18 BUC5 59896123 6.50 (165) 5.25 (133) 4.00 (102) 3.19 (81) 3.25 (83) - 1/2" sweat 7.3 (3.3)
UP 15-18 BUC7 59896124 7.75 (197) 5.25 (133) 4.00 (102) 3.75 (95) 3.25 (83) - 3/4" sweat 8.0 (3.6)