Safety Data Sheet Grip Rite SF Drywall Adhesive Section 1. Identification GHS product identifier : Grip Rite SF Drywall Adhesive Product type : Liquid. CAS # : mixture Address Contact person : Franklin International 2020 Bruck Street Columbus OH 43207 : Franklin Technical Services Telephone : (800) 877-4583 In case of emergency Reference number : Franklin Security (614) 445-1300 : 3620 Product code : 750602 Date of revision : 5/22/2015. Print date : 5/28/2015.
Grip Rite SF Drywall Adhesive Section 2. Hazards identification Disposal Hazards not otherwise classified : Dispose of contents and container in accordance with all local, regional, national and international regulations. : None known. Section 3.
Grip Rite SF Drywall Adhesive Section 4. First aid measures Ingestion : Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel.
Grip Rite SF Drywall Adhesive Section 6. Accidental release measures Personal precautions, protective equipment and emergency procedures For non-emergency personnel : No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Avoid breathing vapor or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate.
Grip Rite SF Drywall Adhesive Section 8. Exposure controls/personal protection Canada Occupational exposure limits TWA (8 hours) STEL (15 mins) Ceiling Ingredient List name ppm mg/ m³ Other ppm mg/ m³ Other ppm mg/ m³ Other Notations propane-1,2-diol ON 1/2013 50 - 10 155 10 - - - - - - - [a] [b] US AIHA 10/2011 Form: [a]Aerosol only. [b]Vapour and aerosol. Mexico Occupational exposure limits Ingredient Exposure limits No exposure limit value known.
Grip Rite SF Drywall Adhesive Section 9. Physical and chemical properties Appearance Physical state : Liquid. [Paste.] Color : Off-white. Odor Odor threshold pH : Not available. : Not available. Melting point : 7 : Not available. Boiling point : 100°C (212°F) Flash point : Closed cup: >93.333°C (>200°F) [Setaflash.] Evaporation rate : <1 (butyl acetate = 1) VOC (less water, less exempt solvents) : 3 g/l Relative density : 1.42 Section 10.
Grip Rite SF Drywall Adhesive Section 11. Toxicological information Conclusion/Summary Skin Eyes : Prolonged or repeated contact can defat the skin and lead to irritation, cracking and/or dermatitis. : This product may irritate eyes upon contact. Respiratory : Inhalation of oil mist or vapors at elevated temperatures may cause respiratory irritation.
Grip Rite SF Drywall Adhesive Section 12. Ecological information Product/ingredient name LogPow BCF Potential propane-1,2-diol -1.07 1.4 low Other adverse effects : No known significant effects or critical hazards. Section 13. Disposal considerations Disposal methods : The generation of waste should be avoided or minimized wherever possible.
Grip Rite SF Drywall Adhesive Section 15. Regulatory information U.S. Federal regulations : TSCA 8(a) CDR Exempt/Partial exemption: Not determined United States inventory (TSCA 8b): All components are listed or exempted.
Grip Rite SF Drywall Adhesive Section 15. Regulatory information 1 Health 1 Flammability 0 Reactivity Special International regulations International lists : Australia inventory (AICS): Not determined. China inventory (IECSC): Not determined. Japan inventory: Not determined. Korea inventory: Not determined. Malaysia Inventory (EHS Register): Not determined. New Zealand Inventory of Chemicals (NZIoC): Not determined. Philippines inventory (PICCS): Not determined.
Grip Rite SF Drywall Adhesive Section 16. Other information Copyright ©2001, National Fire Protection Association, Quincy, MA 02269. This warning system is intended to be interpreted and applied only by properly trained individuals to identify fire, health and reactivity hazards of chemicals. The user is referred to certain limited number of chemicals with recommended classifications in NFPA 49 and NFPA 325, which would be used as a guideline only.