Change for life Owner's Manual Original Instructions Window Type Air Conditioner Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference. If you have lost the Owner’s Manual, please contact the local agent or visit www.gree.com or send an email to for the electronic version.
GJC22BN-D3NRNC5P GJC22BN-D3NRND2P GJC24BN-D3NRNC5L GJC24BN-D3NRNC5M GJC24BN-D3NRNC5P GJC24BN-D3NRND2L GJC24BN-D3NRND2M GJC24BN-D3NRND2P GJC24BN-D3NRNE2M GJC25BN-D3NRNC5P GJC28BN-D3NRNC5P
Contents Operation and Maintenance Installation Operation Notices Installation Notice Safety Precautions..........................1 Precautions.....................................4 Parts Name .....................................5 Installation and Maintenance.........17 Preparation before installation.......19 Operation Guide Function and Control.......................6 Introduction of remote controller ....9 Instruction for fan direction adjusting.........................................
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure they are away from the appliance.
Safety Precautions DANGER Indicates a hazardous situation that, if not avoided, will result in death or serious injury. WARNING Indicates a hazardous situation that, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation that, if not avoided, may result in minor or moderate injury. NOTICE Indicates important but not hazard-related information, used to indicate risk of property damage. Indicates a hazard that would be assigned a signal word WARNING or CAUTION.
Safety Precautions CAUTION When the air filter is to be removed, do not touch the metal parts ofthe unit. ● It may cause an injury. ! ● ● ● ● Do not use strong detergent such as wax or thinner but use a soft cloth. Appearance may be deteriorated due to change of product color or scratching of its surface. ! ● This could injure the pet or plant. ● An It may cause electric shock and damage. ● Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects.
Safety Precautions CAUTION “ ” Operation of Current Device CAUTION: Please contact Customer Service. with a new cord - please contact Customer Service.
Precautions WARNING Air Conditioner should be properly grounded. Incorrect grounding may cause electric shock. purpose socket. Otherwise, it may cause r, otherwise the remote controller may be broken. o not spray water on air conditioner. It may cause electric shock or mal unction. personal injury or damage. r, or put heavy objects.
Parts Name Air outlet frame Fan direction adjusting rod Control panel Air-in panel Power cord NOTE: Panel outlook picture, just for reference, please take the real unit as standard.
Function and Control After putting through the power, air conditioner will give out a sound and indicators on control panel will be on. After that, you operate the air conditioner through remote controller or control panel. Light indicates the unit is in the temperature or delay time Set mode.
Press this button can turn on or turn off air conditioner. Press this button to turn on air conditioner, the unit will operate in Energy Save mode; if the unit is energized after power failure, the unit will still operate according to the status before power failure. Mode button Press this button can your required operation mode in turn. Corresponding indicator will be on.
Ŀ / ŀ button Under temperature setting status, after each pressing of “ Ŀ ” or “ ŀ ” button, temperature will increase or decrease 1°F (°C). Temperature setting range: 61~86°F (16~30°C). Under timer setting status, after each pressing of “ Ŀ ” or “ ŀ ” button, time will increase or decrease 0.5h or 1h. Display 1. Under ON status without timer setting, the operation mode is Auto, Cool, Energy Saver or Dry mode, and the set temperature will be displayed. 2.
Introduction of remote controller Note: This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model GRHVQ¶W have, if press the corresponding button on the remote controller that the unit will keep the original running status.
- / + button Pressing + or - button once will increase or decrease set temperature by 1°F(°C). Hold + or - button for 2s, set temperature on remote controller will change quickly. Release the button after your required set temperature is reached. Under timer setting status, after each pressing of “+” or “-” button, time will increase or decrease 0.5h . Hold “ +” or “-” button, 2s later, time displayed on dual-8 nixie tube will change quickly.
Replacement of Batteries in Remote Controller 1. Press the mark “ ” on back cover of batteries box cover for remote controller with fingers as shown in the fig, and then remove the batteries box cover along the arrow direction. Battery 2. Replace with two #7 (AAA 1.5V) dry batteries. Make sure positions for “+” pole and “-” pole are correct. 3. Reinstall batteries box cover.
Instruction for fan direction adjusting You can adjust the fan direction adjusting rod to select left&right air outlet direction according to your requirement. Fan direction adjusting rod You can adjust the air outlet frame to select up&down air outlet direction according to your requirement.
Clean and Maintenance WARNING Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock. ater to avoid electric shock. ! air conditioner. 1. Open the panel Pull the groove at both sides of panel forcibly to open (below 45 degree) dissolved with neutral abluent, and then put it under the shady place. NOTICE: ation environment, you can increase the clean times.
Malfunction analysis General phenomenon analysis Please check below items before asking for maintenance. If the problem still can't be solved, please contact dealer or professional person. Phenomenon Troubleshooting / of Air conditioner / can't operate Solution Wait after power recovery.
/ blocked? t No fan blowed out from air conditioner / # ! r / under # auto mode?
WARNING If there's below phenomenon, please turn off the air conditioner and disconnect the power immediately. After that, please contact dealer at once. ! # # y.
Installation and Maintenance WARNING % ! ! " p * ! Selection of Installation Location Basic requirement I f f If ! ! @ # " ! :
Requirements for Electric Connection Safety precaution 1. Must follow the electric safety regulations when installing the unit. and air switch. 3. Make sure the power supply matches with the requirement of air conditioner. hazard or malfunction. 4. Please make sure the power supply complies with the requirement of air conditioner. Unstable power supply or wrong wiring may lead to electric 5. Properly connect the live wire, neutral wire and grounding wire of power socket. 6.
Preparation before installation Tools for installation Phillips screwdriver Level bar Screwdriver Scissors Pencil Measuring tape Window type unit Products and spare parts list Sealing strip ( without adhesive) Upper guide rail Sealing strip ( with adhesive)(2) Sponge R1 Sealing sponge of flexible screen(2) Sealing strip ( with adhesive)(2) Type A screw (10) Type C screw (5) Remote controlle Batteries Type E screw (4) Owner's manual 19 Type F screw (2) Supporter (2) Left tripod (1) Ri
Window types installation and requirements Note: The description for below installation is for the standard window. If it’s other types of window, you may need to adjust the window. , you may not need for details. strap, brick or metal.
Installation procedure Step 1: Remove outer case 1. Hold the clasps at the two sides of panel; pull out the panel to a certain degree along the arrow direction and then lift the panel upwards to remove it. Note: For some types of panel, pull out the bottom to a certain degree and then lift the panel upwards to remove it. panel Note: When removing the front case, pull out the bottom and then lift the front case upwards to remove it.
screw at the two sides of outer case, and then pull out the main unit from the outer case. (It is advised that two persons handle this operation, one person holding the outer case and the other person holding the clasp of main unit and pulling out the main unit from outer case.) outer case grounding screw main unit then take out the gasket and binder. This packaging must be removed prior to installing the air conditioner back into the cabinet. gasket Step 2: Install upper guide rail 1.
rails. 2. Stick one sealing strip respectively on the left side and right side of flexible screen installation frame, as shown in the figure. 3. 4.
Tighten screws from inside to outside of outer case. Step 4: Stick sealing strip Stick the sealing strip (with adhesive) at the bottom of window frame. Sealing strip ( with adhesive) Step 5: Install outer case 1. Put the outer case at the windowsill, and the lower guide rail should be stuck to the windowsill.
2. Install the supporter to the tripod with screw; clamp the supporter at the and the unit with screw. left tripod supporter right tripod type F screw outer case type E screw supporter 3. Adjust the position of screw connecting the tripod and supporter into order (Note: The outer case should be placed inclined outwards slightly.) horizontal or inclined about 3-5° 3-5° Can be moved vertically to adjust the gradient of outer case.
screw , with one type C screw. plastic window wooden window Step 7: Plug sealing strip Plug the sealing strip (without adhesive) in the window.
Step 8: Install main unit 1. Ask two persons to push the main unit slowly into the outer case. 2. l cover with screw.
28
Sponge Sticking Method and Procedures 1. Install flexible screen sub-assy. After finishing installation, measure the width L between outer case of air conditioner and window frame. / 2. Take out R1 sponge from the package. Cut off the sponge in rectangular shape with scissors. / 3. Stick sponges evenly on the flexible screen and the screen of window frame. The redundant 2~3mm of sponge in height can be stuffed into the frame for fixing.
Thru-The-Wall Installation NOTE: Consult local building codes prior to installation, or a qualified carpenter. Selec t wall locatio n This air conditioner has a slide-out chassis, so that it can be installed through an outside wall as specified below: Max wall thickness 81/4" IMPORTANT: Side louvers must never be blocked. NOTE: All parts needed for Thru-The-Wall Installation are provided,except a wood frame, shims, and 10 wood screws ( # 10-1" long minimum). Select a wall surface that: 1.
NOTE: If w all thickness is 8-1 /2" or more, add aluminum flashing over bottom of frame opening to assure no water can enter area between inner and outer wall. CAULK AS REQUIRED ALUMINUM FLASHING OVER BOTTOM OF FRAME OVER 81/2" Prepare and Install Cabinet 1. Slide chassis from cabinet. Refer back to Step 1 of Window Mounting. 2. Place cabinet into opening with bottom rail resting firmly on bottom board of wooden frame. 3. Position cabinet to achieve proper slope for water removal .(See FIG.1 below.
6. Install chassis into cabinet by following all steps in Step 8 of Window Mounting.(continued) OPTIONAL: Caulking and installation of trim on interior wall may be done. You can buy wood from your local lumber or hardware supply. On the outside, caulk openings around top and sides of cabinet, and all sides of wood sleeve to the opening. NOTE: See Step 7, Item 3 of Window Mounting Instructions for bottom rail seal location. Masonry Construction 1.
GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 E-mail: Web: www.gree.