Operation Manual
30
10. Starting the charge / discharge process
For charging / discharging, or conditioning a pack, select
the desired program as described below, and then set
suitable values.
If the battery does have a balancer connector, connect the
balancer connector to the balancer input (BALANCER
CONNECTOR) of the charger.
Make sure for the right polarity.
From right handed to left side:
Pin1/1 (GND): Ground = battery1 -,
Pin1/2 (1): + cell 1, Pin1/3 (2): + cell 2, Pin1/4 (3): + cell 3,
Pin1/5 (4): + cell 4, Pin1/6 (5): + cell 5, Pin1/7 (6): + cell 6
Pin2/1 (GND): Ground = battery 2 -,
Pin2/2 (1): + cell 7, Pin2/3 (2): + cell 8, Pin2/4 (3): + cell 9,
Pin2/5 (4): + cell 10, Pin2/6 (5): + cell 11, Pin2/7 (6): + cell 12
Connect the two pole power charging cable of the battery to
the charger output - BATTERY + with the right polarity.
Hold the START button pressed in for about two seconds,
and the charger display, if the balancer connector is
connected or not. With connected balancer connector the
single cell voltages can be displayed, see 16..
You can interrupt the charge process at any time with another
short press on the START button.
Note: if you interrupt the charge process by pressing
the START button, all display parameters are
irretrievably erased.
________________
________________BATTERY CHECK
WAIT PLEASE...
________________
________________LiPo manual
C:2.5A 2000mAh
2
sec.
START
________________
________________CHG 23:40 00863
LP+2.50A 14.01V
2
sec.
3 sec.
________________
________________**INFORMATION***
BALANCER CON.
________________
________________**INFORMATION***
BALANCER NOT CON
START
________________
________________
***LiPo cells***
3 cells (13.73V)
INC
+
-
DEC
If a Li-battery is connected, the charger
will display the cell count of the Lithium
pack, which must be corrected manually
with the INC or DEC buttons, if it is wrong.
START
2
sec.
________________
________________BATTERY CHECK
WAIT PLEASE...
! Caution ! Please
take great care to set
the correct cell
count. and the right
battery type. If you
make a mistake, the
battery could
explode and burst
into flames !
Press the START button again,
and the charger will assess the
battery.
2
sec.
2
sec.