Datasheet

METRACALMC
Multimeter, Calibrator
3-349-564-03
5/10.12
GMC-I Messtechnik GmbH
DQS Certified per
DIN EN ISO 9001
Quality Management System
DAkkS Calibration Certificate as Standard Feature
Deutsche
Akkreditierungsstelle
D-K-15080-01-01
Applications
Process engineers can use the METRACAL MC as a calibrator and a
multimeter simultaneously, e.g. in order to simulate sensor condi-
tions at the input of a transmitter while measuring and saving the
output signal.
If the USB X-
TRA plug-in infrared interface adapter (accessory) is
attached to the instrument, measurement and calibration results
can be uploaded to a PC, where they can be recorded and
printed out as a calibration report. The multimeter can also be
used as a data logger. METRAwin
10/METRAHit
PC software
(accessory) allows for convenient evaluation and display of
measurement data, and METRAwin
90-2 (accessory) can be
used to create, upload and download calibration procedures, as
well as for the generation of calibration certificates.
Calibrator with Loop Current Measuring Instrument
Universal Calibration Standard
Integrated electronics generate mV, V and mA signals. Beyond
this, they’re capable of simulating thermovoltages for various
types of thermocouples for predefined temperatures (C or F), as
well as for various Pt and Ni temperature sensors.
Frequency and Pulse Run Generator
Continuous frequency signals can be transmitted by the
METRACAL MC for testing SPCs, energy metering devices, flow
rates and more. Amplitude is adjustable for the generated square-
wave pulses, which are used to simulate sensor pulses.
Calibration and Simulation
Measuring transducers with a wide variety of input signals
(voltage, thermovoltage, RTD and 2-wire resistance sensors etc.)
can be directly connected and calibrated. If a multimeter is used
(e.g. METRAHIT XTRA), respective values can be measured at the
measuring transducer’s output, transmitted to a PC via an
adapter if desired, displayed with the help of METRAwin
90-2
software and compared with the appropriate calibration
specifications. Setpoint values and actual values are displayed, or
printed as a certificate. When operated in the “mA sink” mode,
the METRACAL MC simulates a 2-wire transmitter and retrieves the
selected current value from the measuring sequence.
Data Storage (16 MBit / 46,000 measured values)
The calibrator is connected to a PC with the attached USB X-
TRA
interface adapter (accessory). Individual values, intervals and
ramps which have been created with the help of METRAwin
90-2
software (accessory) can be saved as data files, uploaded to the
calibrator and saved to non-volatile memory.
Universal calibrator, simulator and multimeter
mA / mV V / C (Pt100/1000, Ni100/1000,
thermocouples: J, L, T, U, K, E, S, R, B, N) / 30 2000
Dual mode – simultaneous calibration and measurement (U/I)
Measuring and encoding in absolute terms and as percentage
(scaled)
Memory for measurement results: 16 MBit
Frequency and pulse run generators: 1 Hz to 2 kHz
Ramp and staircase functions
METRAwin
90-2 interface and calibration software
Transmitter simulator (sink: 0 24 mA)
DAkkS calibration certificate included
Rugged, EMC compliant design
Precision multimeter (V, A, , F, Hz, °C/°F)
30,000 (60,000) digits and triple display
TRMS AC measurement to 1 kHz

Summary of content (6 pages)