Technical Information

BLOWER PERFORMANCE SPECIFICATIONS
9
*MVC960803BNA
Cooling Speed
( @ .1" - .8" w.c. ESP)
*MVC960803BNA
Heating Speed
(@ .1" - .5" w.c. ESP; Rise Range: 35 - 65°F)
Tap Adjust
High-Stage
CFM
Low-Stage
CFM
Ta p A dj ust
High-Stage
CFM
Low-Stage
CFM
Rise
(°F)
A
Minus 10% 566 363
A
Minus 10% 1,082 770 n/a
Minus 5% 598 383 Minus 5% 1,142 812 62
Normal 629 403 Normal 1,202 855 59
Plus 5% 660 423 Plus 5% 1,262 898 56
Plus 10% 692 443 Plus 10% 1,322 941 54
B
Minus 10% 725 486
B
Minus 10% 1,184 831 60
Minus 5% 766 513 Minus 5% 1,250 877 57
Normal 806 540 Normal 1,316 923 54
Plus 5% 846 567 Plus 5% 1,382 969 51
Plus 10% 887 594 Plus 10% 1,448 1,015 49
C
Minus 10% 921 635
C
Minus 10% 1,250 930 57
Minus 5% 972 670 Minus 5% 1,320 981 54
Normal 1,023 705 Normal 1,389 1,033 51
Plus 5% 1,074 740 Plus 5% 1,458 1,085 49
Plus 10% 1,125 776 Plus 10% 1,528 1,136 47
D
Minus 10% 1,107 737
D
Minus 10% 1,256 957 57
Minus 5% 1,169 778 Minus 5% 1,326 1,010 54
Normal 1,230 819 Normal 1,396 1,063 51
Plus 5% 1,292 860 Plus 5% 1,466 1,116 49
Plus 10% 1,353 901 Plus 10% 1,536 1,169 46
*MVC960804CNA
Cooling Speed
( @ .1" - .8" w.c. ESP)
*MVC960804CNA
Heating Speed
(@ .1" - .5" w.c. ESP; Rise Range: 25 - 55°F)
Tap Adjust
High-Stage
CFM
Low-Stage
CFM
Ta p A dj ust
High-Stage
CFM
Low-Stage
CFM
Rise
(°F)
A
Minus 10% 710 462
A
Minus 10% 1,082 780 n/a
Minus 5% 750 487 Minus 5% 1,142 824 n/a
Normal 789 513 Normal 1,202 867 n/a
Plus 5% 828 539 Plus 5% 1,262 910 n/a
Plus 10% 868 564 Plus 10% 1,322 954 54
B
Minus 10% 870 594
B
Minus 10% 1,184 845 n/a
Minus 5% 919 627 Minus 5% 1,250 892 n/a
Normal 967 660 Normal 1,316 939 54
Plus 5% 1,015 693 Plus 5% 1,382 986 51
Plus 10% 1,064 726 Plus 10% 1,448 1,033 49
C
Minus 10% 1,064 712
C
Minus 10% 1,250 914 n/a
Minus 5% 1,123 751 Minus 5% 1,320 965 54
Normal 1,182 791 Normal 1,389 1,016 51
Plus 5% 1,241 831 Plus 5% 1,458 1,067 49
Plus 10% 1,300 870 Plus 10% 1,528 1,118 47
D
Minus 10% 1,238 822
D
Minus 10% 1,256 969 n/a
Minus 5% 1,306 867 Minus 5% 1,326 1,023 54
Normal 1,375 913 Normal 1,396 1,077 51
Plus 5% 1,444 959 Plus 5% 1,466 1,131 49
Plus 10% 1,513 1,004 Plus 10% 1,536 1,185 46
Notes
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
For most jobs, about 400 CFM per ton when cooling is desirable.