User's Manual

Scene Button
User’s Manual
Introduction
The Scene Button is a wireless switch designed to control other associated
devices through the Z-Wave controller. After receiving the signals emitted
by the Scene Button, the Z-Wave controller can then give commands or
operate according to its own settings. Its great compatibility with Z-Wave
products makes it suitable for Z-Wave smart home gateway.
Different scene device actions can be triggered by clicking, double-clicking,
or holding the button. The Scene Button can be conveniently mounted on
any surface and in any position or location at home, e.g. beside the bed or
on the desk.
The Scene Button is also a security Z-Wave device and supports the Over-
The-Air (OTA) feature for the product’s firmware upgrade. If you want it to
be a security device that use secure/encrypted message to communicate in
a Z-Wave network, then a security enabled Z-Wave controller is needed.
Package Contents
Scene Button x 1
User Manual x 1
3M Double-sided tape x 1
Screw x 2
Command Class
Z-Wave Scene Button Command Class Supported
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_SECURITY_2_V1
COMMAND_CLASS_VERSION_V3
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_CENTRAL_SCENE_V2
COMMAND_CLASS_CONFIGURATION_V1
Security
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_ CENTRAL_SCENE_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_VERSION_V3
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
Scene Button Device Information
Basic Device Class: ROUTING_SLAVE
Generic Device Class: SENSOR_NOTIFICATION
Specific Device Class: NOTIFICATION_SENSOR
Detailed description of each Command Class
[COMMAND_CLASS_ZWAVEPLUS_INFO]
The Z-Wave Plus Info Get Command is used to get additional information
of the Z-Wave Plus device in question.
[COMMAND_CLASS_SUPERVISION]
The Supervision Command Class allows a sending node to request
application-level delivery confirmation from a receiving node. The delivery
confirmation includes relevant application-level status information in the
confirmation message. The Supervision Command Class MAY be used for
solitary commands such as Set and unsolicited Report commands.
The Supervision Command Class MUST NOT be used for session-like
command flows such as Get←→Report command exchanges or rmware
update.
[COMMAND_CLASS_BATTERY]
The Battery Command Class is used to request and report battery levels for
a given device.
[COMMAND_CLASS_WAKE_UP]
The Wake Up Command Class version 2 enables read back of the Wake Up
Interval capabilities in a node.
The Z-Wave Scene Button wakes up by wake up timer or presses the
physical button once, it will send Wakeup Notification Command to the
node ID that requires to be reported and stay awake for 10 seconds, if no
WAKE_UP_NO_MORE_INFORMATION command is received.
[COMMAND_CLASS_TRANSPORT_SERVICE]
The Transport Service Command Class supports the transfer of datagrams
larger than the Z-Wave frame.
[COMMAND_CLASS_SECURITY]
The Security Command Class create the foundation for secure application
communication between nodes in a Z-Wave network. The security layer
provides confidentiality, authentication and replay attack robustness
through AES-128.
[COMMAND_CLASS_SECURITY_2]
The Security 2 Command Class is a framework for allowing nodes to
communicate securely in a Z-Wave network. The Security 2 Command Class
provides backwards compatibility to nodes implementing the Security 0
Command Class. Security 2 Command Class also defines a new
encapsulation format, new Security Classes and a new KEX Scheme 1, which
together offers a number of advantages over the Security 0 Command Class.
Security 2 Command Class is scalable and allows more KEX Schemes,
Security Classes and encapsulation formats to be introduced in the future
if necessary.
[COMMAND_CLASS_VERSION]
The Version Command Class, version 3 allows supporting nodes to
advertise capabilities related to the Version Command Class and optionally
provide a detailed list of information regarding implementation on the Z-
Wave chip.
[COMMAND_CLASS_FIRMWARE_UPDATE_MD]
The Firmware Update Meta Data Command Class may be used to transfer
a firmware image to a Z-Wave device.
[COMMAND_CLASS_ASSOCIATION]
The Association Command Class is used to manage associations to Node ID
destinations. A Node ID destination may be a simple device or the Root
Device of a Multi Channel device.
[COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION]
The Multi Channel Association Command Class is used to manage
associations to Multi Channel End Point destinations as well as to Node ID
destinations.
[COMMAND_CLASS_ASSOCIATION_GRP_INFO]
The Association Group Information (AGI) Command Class allows a node to
advertise the capabilities of each association group supported by a given
application resource. Controllers and installer tools SHOULD use AGI
information to support controller-assisted button-to-button association
and GUI-based drag-and-drop association in a plug-and-play fashion.
Centralized gateway-based deployments may create a single association
from the lifeline association group to a central management application.
Group
Name
Description
1 Lifeline Lifeline group, association with 5 nodes.
[COMMAND_CLASS_MANUFACTURER_SPECIFIC]
Manufacturer Specific Command Class, version 2 adds a set of commands
to communicate unique identification, e.g. the serial number, of the
product. Commands not mentioned here remain unchanged as specified
for Manufacturer Specific Command Class, Version 2.
[COMMAND_CLASS_DEVICE_RESET_LOCALLY]
The Device Reset Locally Command Class is used to notify central
controllers that a Z-Wave device is resetting its network specific
parameters.
[COMMAND_CLASS_POWERLEVEL]
The Powerlevel Command Class defines RF transmit power controlling
Commands useful when installing or testing a network. The Commands
makes it possible for supporting controllers to set/get the RF transmit
power level of a node and test specific links between nodes with a specific
RF transmit power level.
[COMMAND_CLASS_CENTRAL_SCENE]
The Central Scene Command Class is used to communicate central scene
activations to a central controller using the lifeline concept.
Product Overview
Product Installation
Battery Installation
1. Slide the battery cover on the bottom of the product to separate it from
the main body.
2. Insert 2 AAA alkaline batteries into the battery compartment and make
sure that the positive and negative polarity of the battery is correct.
3. Slide the battery cover back to the main body.
4. Lock the 2 screws into the screw holes to ensure that the battery cover
is tightly integrated with the main body.
Note:
The package contents do not contain alkaline batteries and must be
purchased by the user.
Scene Button Installation
1. Place the Scene Button on your desktop.
2. Using the double-sided tape: first peel one side of the tape and place
the sticky side onto the battery cover of the Scene Button. Then peel
the other side of the tape and attach it onto a proper location on the
wall.
Product Operation
Function
Operation
Inclusion
Put the Z
Wave Controller into inclusion mode,
and press the button three times in 1.5 seconds to
include the
device
.
Exclusion
Put the Z
-
Wave Controller into exclusion mode,
and press the button three times in 1.5 seconds to
exclude the
device
.
Reset
1.
Remove the battery of the Scene Button first.
2. Power on the Scene Button by reinserting the
battery and operate step 3 within 5 seconds.
3. Press the button three times in 1.5 seconds and
press and hold the button for more than 5
seconds at the 3rd time.
4. The device is excluded and restores to factory
default setting, and the device will be restored
to the unpaired status.
Note: Please use this procedure only when the
network primary controller is missing or otherwise
inoperable.
Send action
to trigger a
scene
Button pressed 1 time
Button pressed 2 times
Button held down
Button released
LED Indicator
LED Signal Status
LED off
1.
Scene
Button is not powered.
2. Scene Button is in standby
mode
.
Red blinking once every 2
seconds for 30 seconds
When
Scene
Button is powered
and has not been added to the Z-
Wave network.
Solid Red for 5 seconds
When
Scene
Button is powered
and has been added to the Z-Wave
network.
Red blinking 1 time Button pressed 1 time successfully.
Red blinking 2 times Button pressed 2 times successfully
Red blinking 3 times
1.
Inclusion process success
2. Exclusion process success
3. Parameter setting success
4.
Button held down
successfully
Red blinking 6 times Low battery
Product Specification
Item Description
Power Supply DC 3V, AAA Alkaline Battery x 2
RF Protocol Z-Wave
RF Frequency
EU:868.4
0
MHz
US:908.40 MHz
JP: 922.50 MHz
KR: 920.9MHz
Data Rate 9.6kbps/40kbps/100kbps
Operation Range 100 feet (About 30M)
LED Indicator RED
Button
x
1 (Inclusion/
Exclusion/
T
rigger
/
Reset)
Waterproof Level IPX4
Operation Temperature -10 ~ 40
Regulatory Approvals CE/ FCC/ TELEC / Z-WavPlus
Dimensions (L*W*H) 80 x 80 x 40.5 mm
*Specification is subjective to change without prior notice.
Regulatory Compliance
CE Caution
Electromagnetic compatibility and Radio spectrum Matters (ERM); Short
Range Devices (SRD); Radio equipment to be used in the 25 MHz to 1,000
MHz frequency range with power levels ranging up to 500 mW; Part 2:
Harmonized EN covering essential requirements under article 3.2 of the
R&TTE Directive.
FCC Caution
This device complies with Part 15 of the FCC rules standard. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including
interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party
responsible for compliance could void the authority to operate equipment.
This device and its antenna must not be co-located or operating in
conjunction with any other antenna or transmitter. This equipment
complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with
V1.0

Summary of content (2 pages)