Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / Measure_kitIVZ.fm / 10.02.2012 Table of Contents Table of Contents Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 The Gigaset N720 DECT IP Multicell System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / security.fm / 10.02.2012 Safety precautions Safety precautions Warning Read the safety precautions and the user guide before use. Use only the power adapter supplied. Use only the recommended, rechargeable batteries (£ page 45) as this could otherwise result in significant health risks and personal injury. Using your telephone may affect nearby medical equipment. Be aware of the technical conditions in your specific location e.g.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / intro.fm / 10.02.2012 Introduction Introduction This document explains the preparations necessary to install a multi-cell DECT network and take measurements for the optimum positioning of the base stations. It also provides technical and practical background information. The Gigaset N720 DECT IP Multicell System The Gigaset N720 DECT IP Multicell System is a DECT multi-cell system for connecting DECT base stations to a VoIP PABX.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / intro.fm / 10.02.2012 Introduction u Gigaset handsets – Up to 100 handsets can be connected and up to 30 calls conducted simultaneously. The following handsets are recommended: Gigaset SL610H, SL400H, S810H, E49H. – Subscribers can accept or initiate calls in all DECT cells with their handset (Roaming), and can also switch between the DECT cells during a call (Handover).
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / intro.fm / 10.02.2012 Introduction Criteria for an optimum DECT wireless network A carefully planned DECT wireless network with adequate coverage is the prerequisite for operating a telephone system that offers good call quality and sufficient call options for all subscribers in all buildings and areas belonging to the PABX.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / intro.fm / 10.02.2012 Introduction Signal transmission The ideal signal transmission of a base station is shaped like a ring, i.e., so that the registered handsets can be the same distance away from the base station in all directions without the wireless signal being interrupted. However, the transmission is influenced by various environmental conditions.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / intro.fm / 10.02.2012 Introduction Overlapping and synchronising For interference-free cooperation in a multi-cell DECT network, the base stations must synchronise. In order to synchronise the base stations and ensure a smooth handover, the cells must overlap. Synchronisation overlap Handover overlap Version 2, 06.08.2010 A sufficient number of large overlapping zones between neighbouring cells must be ensured.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / intro.fm / 10.02.2012 Introduction How to proceed Use the following guide to quickly locate the most important topics. Information on ... ... is located here. Determining the requirements for the telephone network Determine the requirements for the telephone network and collect information about the environmental conditions for the planned DECT wireless network.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / preparation.fm / 10.02.2012 Projecting the DECT network Projecting the DECT network There are a number of conditions to be considered when setting up a DECT network. They affect the subscribers' requirements for the telephone system as well as the technical requirements for the DECT wireless network. These conditions must therefore be recorded and evaluated in a projection phase.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / preparation.fm / 10.02.2012 Projecting the DECT network u What is the basic structure of the building? – What materials and construction types have been used for the buildings? – What type of windows does the building have (e.g., tinted glass)? – What construction changes are expected in the near future? u What disruptive influences can be identified? – What are the walls made of (concrete, brick, etc.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / preparation.fm / 10.02.2012 Projecting the DECT network u Maintain sufficient distance between the base stations as they can interfere with one u u u u another. The minimum distance depends on the circumstances. If no obstacles are present, the required distance can be 5 to 10 metres. If there is an absorbent wall or absorbent furniture between the base stations, 1 to 2 metres may be sufficient.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / preparation.fm / 10.02.2012 Projecting the DECT network Synchronisation planning Base stations that combine to form a DECT wireless network must synchronise with one another to ensure a smooth transition of the handsets from cell to cell (handover). No handover is possible between cells that are not synchronised. They are synchronised via what is known as an air interface, i.e. via the DECT wireless network.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / preparation.fm / 10.02.2012 Projecting the DECT network During the synchronisation planning, make sure that the distance to the base station with sync level 1 is as short as possible from all sides, i.e., that there are as few levels as possible. It makes sense to select the station that is at the centre of your DECT network as the base station with sync level 1.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / preparation.fm / 10.02.2012 Projecting the DECT network The capacity must always be adjusted to the highest possible traffic volume if capacity bottlenecks are to be excluded. Traffic volume Version 2, 06.08.2010 The traffic volume is expressed in "erlangs (E)". One erlang corresponds to the continuous full capacity utilisation of one connection channel in a specific period.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / preparation.fm / 10.02.2012 Projecting the DECT network Alternative calculation for small systems For smaller systems, an approximate evaluation of the traffic volume can be sufficient. Examples: The traffic volume is evaluated for every area as "low", "medium" or "high".
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / preparation.fm / 10.02.2012 Projecting the DECT network Material characteristics and interference factors There are a number of interference factors that influence the range and quality of the transmission in particular. The types of interference factors include: u Interference as a result of obstacles that diminish the signal transmission, creating radio shadows u Interference through reflection that restricts the call quality (e.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / preparation.fm / 10.02.2012 Projecting the DECT network Interference from other cells and networks DECT is very robust against interference from other wireless networks. For example, coexistence with WLAN is not a problem. Most other asynchronous DECT single base stations do not present a problem either. Problems may occur in special cases, such as an environment where there is a very high level of DECT usage.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / preparation.fm / 10.02.2012 Projecting the DECT network Preliminary identification of the positions of the base stations Now plan the positions of the base stations. Take the following into consideration: u The information you have collected regarding the requirements for the telephone network u Your synchronisation planning u The technical conditions for the wireless DECT.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / preparation.fm / 10.02.2012 Projecting the DECT network Positioning the base stations in the plan Now enter the base stations. HS Computers WC/ store Stairs HS u The example shows five base stations. u One base station is used to show how, by drawing in transmission directions for the Version 2, 06.08.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / measure.fm / 10.02.2012 Taking measurements Taking measurements You have: u Determined the requirements for the telephone network (£ page 9) u Planned the number of base stations and their positions (£ page 18) u Set up and operated the measurement equipment. If you are using the Gigaset N720 SPK PRO (Site Planning Kit), you can find information about setting it up on £ page 29.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / measure.fm / 10.02.2012 Taking measurements u Document the progress of the measurement by entering it in the layout plan (horizon- tally and, where applicable, vertically) and in a measurement log. u In order to be able to recognise subsequent changes, it is helpful to document the planned assembly positions of the individual measurement series and their environment with photographs.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / measure.fm / 10.02.2012 Taking measurements Reception power Version 2, 06.08.2010 The reception field strength is measured to assess the quality of transmission. The reception power (proportional to the field strength) is displayed on the measuring handset in dBm (£ page 48). A very good reception power is approximately –50 dBm. Systems that are measured at up to –60 dBm generally offer a good quality.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / measure.fm / 31.10.2013 Taking measurements Connection quality Version 2, 06.08.2010 In principle, the measurement of the field strength should always be supplemented by a check of the connection quality. Interference, e.g., through reflection or external systems that influence the voice quality, can also occur with good reception power.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / measure.fm / 10.02.2012 Taking measurements Measuring the wireless range of the planned base stations Take two different measurements. §§1§§ Measure the connection quality between the measuring handset and measuring base station in their wireless cells to ensure that sufficient voice quality is guaranteed at every position in the required coverage area.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / measure.fm / 10.02.2012 Taking measurements Measuring the cell of a base station ¤ Temporarily secure the measuring base station in the position in which the base sta¤ ¤ ¤ ¤ ¤ tion is to be installed. Establish a telephone connection between the two measuring handsets or activate the continuous test tone of the measuring base station (£ page 38).
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / measure.fm / 10.02.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / measure.fm / 10.02.2012 Taking measurements ¤ Install the measuring base station at this location and take the measurements as for the first position. ¤ Enter the results in the plan and the measurement log. ¤ Now take this measurement for all planned assembly locations.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / measure.fm / 10.02.2012 Taking measurements Evaluating measurements The graphical display of your measurement results in the layout plan shows the overlap areas of the individually planned base stations. D A In the example, limitation lines are drawn for the wireless coverage for base stations A and D. The overlap areas are very good for both stations; synchronisation is also guaranteed between A and D.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / mess_kit.fm / 10.02.2012 Working with the Gigaset N720 SPK PRO Working with the Gigaset N720 SPK PRO The Gigaset N720 SPK PRO (Site Planning Kit) helps you to plan and install your DECT multi-cell system. It contains one measuring base station, two measuring handsets and further helpful accessories for exact determination of the DECT environmental conditions for the planned network and is delivered in a case.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / mess_kit.fm / 10.02.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / mess_kit.fm / 10.02.2012 Working with the Gigaset N720 SPK PRO Before you begin Please note that the measuring devices run on batteries that must be charged before you start taking measurements. Bear this in mind when planning your time. You need eight batteries for the measuring base station, provided as a battery pack. The case contains a charging device for charging the battery pack. The charging time is approx. three hours.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / mess_kit.fm / 10.02.2012 Working with the Gigaset N720 SPK PRO ¤ Insert the battery pack into the battery ¤ compartment in the base carrier §§3§§. Slide the lid onto the battery compartment §§4§§ until it clicks into place. 4 3 Charging the batteries The measuring base station is connected to the power supply by means of a cable §§1§§.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / mess_kit.fm / 10.02.2012 Working with the Gigaset N720 SPK PRO Please note u The measuring station has sufficient power when the LED on the front is illuminated. u To save energy, position the switch on "Charge" when you do not need the device. Alternative power supply The measuring base station is supplied with power via the battery pack inserted in the battery carrier.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / mess_kit.fm / 10.02.2012 Working with the Gigaset N720 SPK PRO Connecting to a switch with PoE functionality (Power over Ethernet). ¤ Connect the LAN socket on the measuring base station §§1§§ to a connection on an Ethernet switch §§2§§. Use a shielded Ethernet cable. 2 1 Mounting the measuring base station on the stand Version 2, 06.08.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / mess_kit.fm / 10.02.2012 Working with the Gigaset N720 SPK PRO Starting up the measuring handset ¤ Remove the measuring handsets and accessories from the case.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / mess_kit.fm / 10.02.2012 Working with the Gigaset N720 SPK PRO Initial charging and discharging of the batteries The correct charge status can only be displayed if the batteries are fully charged and discharged first. ¤ Charge the handset in the charger for 8.5 hours. ¤ After charging, remove the handset from the charger and only replace it when the batteries are fully discharged.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / mess_kit.fm / 10.02.2012 Working with the Gigaset N720 SPK PRO Operating the measuring handset Please note This section only describes the functions of the handset relevant for measurements. For information on the standard functions of the Gigaset S810H handset, see the user guide for the device. See the product page at www.gigaset.com.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / mess_kit.fm / 10.02.2012 Working with the Gigaset N720 SPK PRO Display not in idle status -30dBm-1-04-50H-100 If the display is not in idle status, it shows the measurement data at the top edge.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / mess_kit.fm / 10.02.2012 Working with the Gigaset N720 SPK PRO Activating/deactivating speaker mode You can also test the quality of the connection via the loudspeaker instead of via the headset. d Press the speaker key to switch between earpiece mode and speaker mode. ¤ In this case, place the plastic cover supplied on the headset socket. This improves the quality in speaker mode.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / mess_kit.fm / 10.02.2012 Working with the Gigaset N720 SPK PRO Changing the settings for metering mode In the service menu, you can change the unit of measure and the measurement interval for metering mode.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / specialEnvironment.fm / 10.02.2012 DECT installations in special environments DECT installations in special environments The Projecting the DECT network and Taking measurements chapters describe all prerequisites and steps for planning a DECT network. In addition to the examples and applications described there, this chapter contains notes for special construction or topographical requirements.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / specialEnvironment.fm / 10.02.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / appendix.fm / 10.02.2012 Environment Customer care and help Questions? For rapid assistance, refer to this user guide or visit www.gigaset.com/pro. The trade outlet where you bought your PABX will be happy to help with further questions relating to your Gigaset Professional PABX. Questions and answers If you have any queries about the use of your telephone, visit our website at www.gigaset.com/pro.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / appendix.fm / 10.02.2012 Appendix health. It is a precondition for reuse and recycling of used electrical and electronic equipment. For more detailed information about disposal of your old appliance, please contact your local council refuse centre or the original supplier of the product. Appendix Care Wipe the base station, charging cradle and handset with a damp cloth (do not use solvent) or an antistatic cloth.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / appendix.fm / 10.02.2012 Appendix Specifications Handset batteries Technology Size Voltage Capacity Nickel-metal-hydride (NiMH) AAA (Micro, HR03) 1.2 V 700 mAh Each handset is supplied with four recommended batteries. Operating times/charging times for batteries The operating time of your Gigaset devices depends on the capacity and age of the batteries and the way it is used. (All times are maximum possible times).
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / appendix.fm / 10.02.2012 Appendix Accessories Ordering Gigaset products You can order Gigaset products from your specialist retailer.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / glossary.fm / 10.02.2012 Glossary Glossary Bandwidth The bandwidth defines the size or transmission capacity of a transmission channel, or, more precisely, the difference between the lowest and highest possible frequency on a transmission channel. The bandwidth is specified in Hz. For digital data transmission, the bandwidth determines the data volume that can pass through a transmission channel in a specified period, i.e.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / glossary.fm / 10.02.2012 Glossary The selection of the codec for the telephone connection therefore influences the voice quality and, via the available bandwidth, the possible number of usable channels per base station. Codecs in £Broadband mode G.722 Excellent voice quality. The G.722 codec works at the same bit rate as G.711 (64 kbit/s per speech connection) but with a higher sampling rate.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / glossary.fm / 10.02.2012 Glossary Erlang Unit which measures the traffic volume in a communications system. One erlang corresponds to the continuous full capacity utilisation of one connection channel in a specific period. Frame For radio transmission, DECT uses a time multiplex procedure with a frame structure for separating the uplink and downlink for each radio channel (£Frequency).
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / glossary.fm / 10.02.2012 Glossary RFPI Radio Fixed Part Identity ID for a base station in a multi-cell DECT network. It includes the number (RPN) and an ID for the DECT Manager. A handset uses it to recognise the base stations it is connected to and the DECT network to which it belongs. Roaming Possibility for a subscriber with a DECT handset to accept or make calls in all cells of a DECT network.
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / Measure_kitSIX.fm / 10.02.2012 Index A Authorisation . . . . . . . . . . . . . . . . . . . . . . . . . 44 B Base carrier . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 mounting on the stand . . . . . . . . . . . . . . 34 Base stations minimum distance . . . . . . . . . . . . . . . . . . 11 planning locations . . . . . . . . . . . . . . . . . . 18 Batteries charging . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / Measure_kitSIX.fm / 10.02.2012 M P Material characteristics . . . . . . . . . . . . . . . . 16 Measurement performing . . . . . . . . . . . . . . . . . . . . . . . . . 20 preparing . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Measurement interval . . . . . . . . . . . . . . . . . 40 Measurement log . . . . . . . . . . . . . . . . . . 25, 27 Measurement process . . . . . . . . . . . . . . . . . 25 Measurement result . .
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2316-L101-2-7619 / Cover_back.fm / 10.02.