User guide

Signet 2000 Micro Flow Sensor
Technical Notes:
Horizontal surface mount (±30°) recommended for
optimum performance.
Suitable for clean fl uids only. Suspended solids will cause
mechanical failure.
1/4 in. NPT or ISO 7/1 - R1/4 (male) port connections
NEMA 4X/IP65 splashproof enclosure
2. Recommended Sensor Position
1. Compatible Instrument Wiring
Technical Notes:
Use 2-conductor twisted-pair shielded cable for sensor cable splices up to 300 m (1000 ft) max.
Maintain cable shield through cable splice.
Route sensor cable away from AC power lines.
AUX power required when used with any Signet 8550 Process Pro Flow Transmitter.
Signet 2000
Input
Gnd.
10 kΩ
+
5 to 24
VDC
-
Black
Shield
Red
Other
Instrument
Black (5 to 24 VDC)
Red (Signal out)
Shield (DC return)
Blk
Power
Red
Freq. input
Shld
Gnd
Other
Instrument
Signet
Instrument
30°30°
Recommended
mounting angles
Vertical mounting
not recommended
SAFETY INSTRUCTIONS
1. Depressurize and vent system prior to installation/removal.
2. Confi rm chemical compatibility before use.
3. Do not exceed maximum temperature/pressure specifi cations.
4. Wear safety goggles or faceshield during installation/service.
5. Do not alter product construction.
*3-2000.090-1*
3-2000.090-1 Rev. E 7/09 English