Technical Diagram

- 1 PWRcell Inverter - 1 CT Kit (included)
- 6 PV Links - 1 ATS Kit
- 2 PWRcell Battery
This design shows a Generac PWRcell system with an external
Automatic Transfer Switch configured for light load backup
(less than 8 kW continuous, 10 kW peak power). Use this
system configuration to provide backup power to the main
service panel in accordance with NEC 702.4(B) and Sect. 220.
This configuration is acceptable with 200A or larger utility
services.
Powered by REbus (DC Voltage)
AC Voltage
30A
30A
30A
30A
Power Conversion
PWRcell
TM
Inverter
Generac
PowerCore
Router
Ethernet (CAT5)
50A
Main Distribution
Panel
CT (CAT5)
N
E
Automatic
Transfer
Switch
Generac
®
RXS
L
ATS Kit
AC Grid
M
ATS (CAT5)
40A
Storage
PWRcell Battery
PV Array
PV Optimization
PV Link
TM
Substring Optimizer
REbus
TM
DC nanogrid
FOR REFERENCE ONLY; NOT FOR CONSTRUCTION.
*Installer responsible for code compliance.
*Refer to product manuals for additional installation
details and requirements.
Reference Code-
2415-01
Small Home Backup / Solar + Storage
Page 8 of 11
Part No. A0000521683 Rev. D 03/10/2020
© Generac Power Systems, Inc. All rights reserved
Generac Power Systems, Inc.
S45 W29290 Hwy. 59
Waukesha, WI 53189