Installation guide

Installation
30" Built-I_ ( o_vection Ove_s
208V
Electrical
supply
_ Th_se OX_ llS aye pF_-wh-_ d _)t- connec-
]tion lo 24¢) volt, 60 Hz., suppl). If connecting
to a 208 _olt supply modifications must be made.
to _l 2'08 vol
If connecting to a 208 volt, 60 Hz., supply, a jumper
mtlst be tlsed across two tetmitlals.
For double ovens, there are lwojumpers, one fin- the
upper oven, one for the lower oven.
For single ovens there is one jumper.
Single ovens,
double ovens-
(upper oven)
Jumper
LoosenScrews
Jumper Tighten Screws
To connect to 208 volt circuit:
Remove the access panel(s) located on the back of
the ovens.
Loosen the first and second screws ill the terminal
block as shown.
Remove the jumper and place between the fh-st and
second screws, tighten the screws to hold the
jumper in place.
Replace the access panel(s).
Double ovens-
(lower oven)
I)ouble ovens-Lower
JumperL00 n
o
Jumper
Loosen Screws
Jumper Tighten Screws
10