Installation guide

6 31-11062-1
Installation Instructions
1
B
CUTOUT FOR FLUSH MOUNT INSTALLATION - TRIM KIT REQUIRED
A
47” is the required minimum installation height. Oven
may be installed higher based on owner preference.
B
Extended depth cabinet is required. Drywall is
acceptable as back enclosure.
C
Platform must be able to support 200 lbs (91 kg).
D
Solid enclosure required on the top, bottom, left and
right sides and back of oven.
E
Junction box location (May also be located in
adjacent cabinet).
F
Standard depth cabinet requires modification of
interior wall.
G
1” overlap required top and bottom to allow for
fastening trims to cabinet. This can be achieved with
blocking which is secured to the cabinet.
SIDE VIEW FRONT VIEW
EXTENDED DEPTH CABINET INSTALLATION
ELEC
30” (76.2) ± 1/16”
5” (12.7) max.
10” (25.4) max.
Solid enclosure
required on the
top, bottom, left
and right sides,
and back of oven
Recommend
5/16” (0.8) min. for
overlap of oven
over side edges
of cutout if using
optional side trims
Recommend
1 3/16” (3) min.
for overlap of
oven top and
bottom over
edges of cutout
for clearance to
trim overlap
E
D
27 5/8” (70.2)
min. cutout
28 1/4” (71.7)
± 1/16”
5 1/8”
(13.0)
± 1/16”
1” (2.5)
1” (2.5)
7/8” (2.2)
30 1/4” (76.8)
4 11/16” (11.9)
± 1/16”
7/8”
Cabinet Door
41 7/8”
(106.4)
47” (119.4) min
B
A
G
G