GE Oil & Gas GE’s Mooney* Specialty Regulators The Handloader, Mity-Mite and Powereactor Regulators
| GE Oil & Gas
Mooney* Handloader Regulator This small volume, high pressure regulator has become the standard of industry and science. These instruments are often referred to as “Loaders” because of their many years of extensive use maintaining constant, extremely accurate pressure control in the “loading” of dome regulators. However, their accuracy, trouble-free performance, and versatility have led to hundreds of other applications in static, mobile and airborne services.
Mooney* Handloader Pressure Reducing Regulator Model 15L w/ Relief System 16 L 15LH w/Relief System 16 LH 15 LX w/Relief System 16 LX 15 LHX w/Relief System 16 LHX Inlet Pressure Temperature Range Cv 6000 psi -65° to 165° F 0.06 -65° to 165° F 0.
Mooney* Handloader Pressure Reducing Regulator Model Max Inlet (psig) Outlet Range (psig) 6000 2-25 3-60 5-150 8-300 10-750 Outlet Rise/ 1000 psig inlet drop Average Lockup (psig) 0.06 3 3 3 5.4 11 1.7 1.7 1.7 3 6 6000 2-25 3-60 5-150 8-300 10-750 0.06 3 3 3 5.4 11 1.7 1.7 1.7 3 6 6000 2-25 3-60 5-150 8-300 10-750 0.018 1 1 1 1.8 3.7 1.7 1.7 1.7 3 6 16LX 6000 2-25 3-60 5-150 8-300 10-750 No 0.18 1 1 1 1.8 3.7 1.7 1.7 1.7 3 6 15LH 6000 10-1000 10-3100 Yes 0.
Mooney* Handloader Pressure Reducing Regulator Model Temperature Range 153 -65° to 165° F Cv 0.17 155 -65° to 165° F 0.04 Model Basic Fig # Outlet Range Code End Connection 153 11409 2-25 psi 3-60 psi 5-150 psi 8-300 psi 10-750 psi 10-1000 psi A B C E F H 1/4”NPT P2 2-25 psi 3-60 psi 5-150 psi 8-300 psi 10-750 psi 10-1000 psi A B C E F H 1/4”NPT P2 155 11410 Order Code = Code P2 NOTE: Other configurations may be available, please contact Oil & Gas.
Mooney* Mity-Mite Regulator The Pressure Reducing Mity-Mite is a direct acting, self-contained gas dome regulator of compact design, weighing approximately 2 lbs. These regulators have a set of integral needle valves for internal dome loading for gas service. An auxiliary connection is provided in the dome for external dome loading.
Mooney* Mity-Mite Regulator Model 94 Inlet Pressure 5000 psi Max. Outlet Pressure 3000 psi End Connections 1/4” FNPT Cv 0.1 with 3/32” orifice 0.6 with 3/16’ orifice Weight Aluminum - 1.6 lbs Stainless Steel - 4.6 lbs. Model Diaphragm Size (Inches) Max Inlet (psig) Max Outlet (psig) Orifice Cv Outlet rise/100 psig Inlet Drop Average Lock up (psi) Internal Loading Option* External Sensing Option* Valve Type 94 2 5000 3000 3/32” 0.14 0.
Mity-Mite Back Pressure Regulator Specifications Model Connections Cv Control Range 90W S90W SD90W 1/4” FNPT 0.44 10-2000 psi 91LW S91LW SD91LW 1/4” FNPT 0.44 25-400 psi 91W S91W SD91W 1/4” FNPT 0.38 100-2000 psi 91W S91W SD91W 1/4” FNPT 0.17 100-3000 psi 91 1/4” FNPT 0.
Mooney* Powreactor Dome Regulator The Mooney* Powreactors are direct-acting, self-contained, dome-loaded, pressure reducing regulators. Control pressure sensing is normally accomplished within the Powreactor without the need for external tubing and valves. This achieves a clean silhouette and minimum envelope size while also making the Powreactor capable of sustaining much rougher handling than the average regulator.
As you consider the proper regulator for your application, please consider the balanced and unbalanced valve configurations that are available for the Mooney* Specialty Regulator. The normal configuration of the Mooney* regulator is Internal Sensing. This method conveys outlet pressure to the bottom of the diaphragm through an internal sensing passage. This method provides quick response and accurate control.
Model Inlet Pressure Maximum Outlet Pressure Weight Internal Sensing with Alternate External Sensing Connection 3/8” MS16142 202B 6000 psi 6000 psi 32 lbs. 212B 6000 psi 6000 psi 32 lbs Internally loaded through integral needle valves External Dome Loading connection: 1/4” MS16142-4 202F 3500 psi 3500 psi 12 lbs Balanced Valve Example Unbalanced Valve Example Unbalanced Valve Example Model Basic Fig. # Body/ Dome Material Trim Material End Conn.
Model Basic Fig.
Model 402E Basic Fig # Body/Dome Material End Connection Orifice Size Max Inlet (psi) Max Outlet (psi) Temperature Range 11487P106A Forged Carbon Steel Forged Carbon Steel Forged Carbon Steel Forged Carbon Steel Forged Carbon Steel 2’ FNPT 1/2” 3600 1500 0 to 165° F 2’ FNPT 3/4” 3600 1500 0 to 165° F 2’ FNPT 1” 3600 1500 0 to 165° F 1-1/2’ FNPT 1-1/2’ FNPT 1/2” 6000 3000 0 to 165° F 1” 6000 3000 0 to 165° F 11487P107A 11487P108A 11487P088A 11487P086A Order Code = Rubber G
Model Basic Fig # Body/Dome Material End Connection Orifice Size Max Inlet (psi) Max Outlet (psi) Temperature Range 412E 11489P109A Forged Carbon Steel 2’ FNPT 1/2” 3600 1500 0 to 165° F 412F 11311P109A Nickel Coated Carbon Steel 2’ FNPT 3/4” 6000 3000 -65° F to 165° F Order Code = 412E Weight: 80 lbs Rubber Goods Valve Seal & Gasket Body Plug Gasket Nitrile PCTFE PCTFE Nitrile PCTFE PCTFE Trim Material 412F Weight: 85 lbs Internal loaded integral needle valves External
Powreactor Dome Regulator Chart Model Diaphragm Size Max Inlet (psi) Max Outlet (psi) Orifice (inches) Cv Outlet rise per 100 psi Inlet Drop Average Lockup (psi) Internal Loading Option• External Loading Option• Valve Type 94 2 5000 3000 3/32 0.14 94 2 5000 3000 3/16 0.65 0.41 1 Yes No Unbal 2.3 6.1 Yes No Unbal 112B 2 6000 6000 3/16 0.5 0.3 7.1 Yes No Bal 112BR 2 6000 6000 3/16 0.5 0.18 7.1 Yes No Bal 202B 3 6000 6000 202B 3 6000 6000 3/16 0.
Dome Loading Methods Dome regulators use gas pressure instead of a spring force to push down on the diaphragm to establish an outlet set pressure. A pressure down stream that is lower than the dome pressure results in the diaphragm being pushed down which opens the valve. Conversely, the valve closes as the outlet increases above the dome pressure. The dome loading methods include the use of internal loading needle valves or by the use of a Model 15 Handloader or other method.
Regulator Selection Considerations: ■■ Is the flow media liquid or gas? ■■ Is it for pressure reducing or back pressure service? ■■ What is the minimum and maximum inlet pressure? ■■ What is the minimum and maximum outlet pressure? ■■ What is the specific gravity of the media? ■■ What is the minimum and maximum flow rate? ■■ What are the connection requirements? ■■ Other considerations: ❖❖ Unbalanced Effect = Outlet pressure change affected by the inlet pressure.
Whether it is the simple operation of the Handloader, the compact Mity-Mite or the configurable Powreactor, the Mooney* Specialty Regulators provide a stellar history of performance in the most demanding industrial, laboratory, aero space and defense applications. PSI Pressure Reducing 10,000 For pressure reducing applications, the Mooney* Specialty Regulator line are typically used for high inlet pressure applications but they work equally well for low inlet pressures.
GE Oil & Gas 2822 S. 1030 West Salt Lake City, UT 84119 T: +1 801.487.2225 F: +1 801.487.2587 Visit us online at: www.ge.com/energy ©2014, General Electric Company All Rights Reserved *Trademark of General Electric Company GEA19588 Mooney Specialty Regulator Rev 07.