Owner's manual

For answers to your Monogram
®
or GE
®
appliance
questions, visit our website at geappliances.com
or call GE Answer Center
®
service, 800.626.2000.
220593
Listed by
Underwriters
Laboratories
3-1/4*
Cooktop
2-1/2**
Required
28-1/2
19-5/8
29 3/4
PHP900DM
PP945WM/BM
PP944TT/DT
PP932BM
PP912TM/KM/BM
JP356WM/BM
JP336DD
21-3/8
* Depth of unit at conduit connection location (rear)
is 6-1/4" on models PP975/945 and 4-3/16" on
models CP350/650, PP944/962/932/912, and
JP656/356/336. Depth of unit at baffle (front) is
4-5/8" on models PHP960/900.
**Raised bull nose countertops may require up to
3/8" additional clearance to prevent interference
with curved front.
Electrical junction
box 16" MIN.
below countertop
30" MIN. to
unprotected
cabinet
Cut should not interfere
with cabinet structure
at front
1-1/2" MIN.
(30" cooktop)
2" MIN. (Induction
and 36" cooktops)
clearance to side
wall from cut-out
1-1/2" MIN.
(30" cooktop)
2" MIN. (Induction and
36" cooktops) clearance
to side wall from cut-out
15" MIN.
to cabinet
1-3/4" to
rear wall
13" MAX.
depth
Note: Check local codes for required breaker size
Important: Requires a 5” free area between
the bottom of the cooktop to any combustible
material, i.e., shelving. Free area not required
when installing wall oven underneath cooktop.
Refer to installation instructions. Requires a
15” minimum from cooktop to adjacent
overhead cabinets. Units are furnished with
a 48” flexible armored cable.
Note: 30” Ribbon cooktops are approved for use over select GE 30” Single
Wall Ovens and Warming Drawers. All 30" ribbon cooktops can be installed
over 27" wall ovens and warming drawers. Refer to cooktop and wall oven/
warming drawer installation instructions packed with product for current
dimensional data. If installed with a GE Profile
Telescopic Downdraft System,
consult both the cooktop and downdraft installation instructions packed
with product before installing.
Cooktop gas/electric supply may need to be
re-routed to install downdraft.
The countertop must be at least 26" deep with
a flat surface area of 23-1/2" or more, front to back. In addition, other
clearances to the front edge of the countertop must be considered.
Consult cabinet and countertop manufacturer’s specs for flush mount
installation prior to install. Before installing, consult installation
instructions packed with product for current dimensional data.
KW Rating
240V
7.8
208V
5.9
Breaker Size
240V
40 Amps
208V
30 Amps
Dimensions and Installation Information (in inches)
Specification Revised 10/13
PP945WM/BM
GE Profile Series 30" Built-In CleanDesign Electric Cooktop

Summary of content (2 pages)