Spec Sheet

AZ9VH12EBM
GE Zoneline
®
Heat Pump Single Package
Vertical Air Conditioner 265 Volt
Specification Revised 9/21
PERFORMANCE DATA
- Nominal Cooling Capacity - 12,000 BTUh
- Cooling Capacity Range @95F - 5,000-16,000 BTUh
- EER - 11.8
- Heat Pump Capacity Range @47F - 5,000 - 16,000 BTUh
- COP @ 47F - 3.4
- Make Up Air SCFM Range - 37-90 (no filter) 18-70 (with MERV 13 filter)
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
28
36
23
265V POWER CONNECTION REQUIREMENTS (RESISTANCE HEAT)
POWER
CONNECTION KIT
RAK515D RAK520D RAK530D
Heater Watts 2450 3450 5000
MCA 15 20 30
Recommend
Protective Device
(MOCP)
15 amp
time-delay fuse
or breaker
20 amp
time-delay fuse
or breaker
30 amp
time-delay fuse
or breaker
MINIMUM CLEARANCES:
FRONT-ACCESS CLOSETS
-Allow 3" in front of unit, Allow 3" on each side of unit.
SIDE-ACCESS CLOSETS
- Allow 5" in front of unit, Allow 3" on each side of unit.
REQUIRED COMPONENTS FOR INSTALLATION
- Drain Platform (RAVDPLAT)
- Plenum
- Exterior Grille
- Return Air Grille/ Access Panel
- Remote Thermostat
- Power Connection Kit
For answers to your Monogram, GE Café
, GE Profile
or GE Appliances
product questions, visit our website at geappliances.com or call
GE Answer Center
®
Service, 800.626.2000.