GE Appliances Room Air Conditioners Owner’s Manual & Installation Instructions AVM14 AVM15 AVM18 AVM22 AVM24 AVN24 AVP24 Part. No. 23-11-2129N-002 Pub. No.
Safety Instructions Operating Instructions Operating Instructions Installation Instructions Troubleshooting Tips Safety Precautions . . . . . . . . . . . . .3 Use of Extension Cords . . . . . . . . .3 Use of Adapter Plugs . . . . . . . . . . .3 Installation Instructions Safety Information Controls . . . . . . . . . . . . . . . . . . .4, 5 Care and Cleaning . . . . . . . . . . . . .6 Welcome to the GE family. We’re proud of our quality products and we are committed to providing dependable service.
Safety Instructions IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury. SAFETY PRECAUTIONS ■ This air conditioner must be properly installed in accordance with the Installation Instructions before it is used. ■ Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
WARNING! USE OF EXTENSION CORDS – 115-Volt models only Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord. However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.
Safety Instructions About the controls on the air conditioner. The controls will look like one of the following. (Features and appearance will vary.) OFF HIGH FAN OFF ENER HIGH COOL S V LOW COOL LOW COOL HI FAN LOW COOL HI COOL HIGH COOL Operating Instructions GY A LOW FAN LOW FAN MED COOL ER MODE CONTROLS Your model will have one of the above controls.
Additional controls and important information. Vent Control When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside. Closed Open Air Direction Two levers on each side of the grille let you control the air direction left or right. Fingertip pressure on the tabs adjusts the air direction up or straight ahead. Do not adjust the louvers down any lower than straight out.
Safety Instructions Preparing to install the air conditioner. Read these instructions completely and carefully. Before You Begin NOTE TO CONSUMER: Keep this Owner’s Manual and Installation Instructions for future use. Do not change the plug on the power cord of this air conditioner. IMPORTANT NOTES: For personal safety, this air conditioner must be properly grounded. Aluminum house wiring may present special problems—consult a qualified electrician.
Safety Instructions Window Installation Instructions Parts Included 2 support brackets Operating Instructions 2 sill brackets Foam top window gasket Case 2 filler panels Installation Instructions Window locking bracket Customer Service Troubleshooting Tips 5/8″ machine screws (2) and nuts (2) 8 5/8″ carriage bolts (2) and nuts (2) 1″ screws (4) 5/8″ screws (5) 3/8″ hex head screws (8)
Safety Instructions Read completely, then follow step-by-step. 1 Window Requirements ■ These instructions are for a standard doublehung window. You will need to modify them for other types of windows. ■ The air conditioner can be installed without the Operating Instructions filler panels if needed to fit in a narrow window. See the window opening dimensions to the right. 18 5⁄8″ min. ■ All supporting parts must be secured to firm 303⁄4″ to 46 1⁄2″ (with filler panels) wood, masonry or metal.
Safety Instructions Window Installation Instructions 3 Remove the Air Conditioner from the Case A Remove the air filter. Lift the top of the filter and gently pull it up. C Remove one screw from each side of the case. Keep these ground/anti-theft screws so they may be replaced at the end of the installation. Operating Instructions Case B Remove the 2 screws and lift off the front grille.
A Open the window and mark the centerline on the stool. C Close the window until it touches behind the top retainer bar. D Secure the case through the case track into the window stool on each side, using two 1″ screws. Mark centerline Carefully place the case in the window and align the center of the bottom tie bar with the centerline on the window stool. Do not release your grip on the case until the window is in its final position.
7 Install the Window Filler Panels and Locking Bracket A B Extend the filler panels to fill the window opening. Secure the panels using four 5/8″ long screws. C Attach the window locking bracket with a 5/8″ screw. 8 Customer Service Troubleshooting Tips Installation Instructions Operating Instructions Safety Instructions Window Installation Instructions 12 Install the Window Gasket and Replace the Air Conditioner A Cut the foam top window gasket to the window width.
Safety Instructions Through-the-Wall Installation The case may be installed through-the-wall in both existing and new construction. Read completely, then follow step-by-step. 1 IMPORTANT: ■ Any side louvers must project on the outdoor side of the wall. ■ The room side of the case must project into the room at least 1 1/ 2″ from the finished wall. Remove the air conditioner from the case. For specific instructions, refer to the Window Installation Instructions.
Safety Instructions Operating Instructions Troubleshooting Tips Save time and money! Review the chart below first and you may not need to call for service. Problem Possible Causes What To Do Air conditioner does not start The air conditioner is unplugged. • Make sure the air conditioner plug is pushed completely into the outlet. The fuse is blown/circuit breaker is tripped. • Check the house fuse/circuit breaker box and replace the fuse or reset the breaker. Power failure.
Safety Instructions Air Conditioner Warranty All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. For service, call 800-GE-CARES. GE Will Replace: One Year From the date of the original purchase Any part of the air conditioner which fails due to a defect in materials or workmanship. During this full one-year warranty, GE will also provide, free of charge, all labor and in-home service to replace the defective part.
Safety Instructions Service Telephone Numbers. GE Answer Center® 800.626.2000 The GE Answer Center® is open 24 hours a day, 7 days a week. In-Home Repair Service 800-GE-CARES (800-432-2737) Operating Instructions Expert GE repair service is only a phone call away. Special Needs Service 800.626.2000 800-TDD-GEAC (800-833-4322) Installation Instructions GE offers, free of charge, a brochure to assist in planning a barrier-free kitchen for persons with limited mobility.