Logic HE Balanced Flue Log Installation User Instructions

37
Servicing Instructions - Replacing Parts
7a.2 Undo the red and green thermocouple connections (A)
and the white ignition lead (B) from the gas valve,
see Diagrams 15.
NOTE: Ensure the correct orientation when replacing, see
Diagram 15 detail.
15
A
B
White
Green
Red
7a.3 Remove the screw and sealant from plate, see
Diagrams 16.
16
Plate
Screw
When replacing the cover plate ensure silicone sealant
is used to seal the aperture.
7a.4 Gently bend the tabs back to remove the pilot cage, see
Diagram 17.
17
7a.5 Remove the 2 screws securing the pilot assembly,
see Diagram 18.
18
7a.6 Replace with a new pilot assembly and check the spark gap,
see Diagram 19.
19
NOTE: Ensure the correct orientation when replacing.
7a.7 After reassembly check for gas soundness and carry out a
flame failure functional check as detailed in the Fault Finding
chart, especially the time it takes for the mag unit to close.
7b. Slide Control
7b.1 Undo the pilot pipe from the pilot unit, see Diagrams 20.
20
Pilot Pipe
7b.2 Undo the thermocouple connection from the gas valve, see
Diagrams 21.
21