User's Manual Part 3

164
Functions of Model Menu (Helicopter Functions)
Selectthefunction
nameandreturntothe
precedingscreenby
touchingtheRTNbutton
orpushingtheHome/Exit
button.
<SensorTouch™>
GOVERNOR mixing
When using a Futaba governor, this function is
used to switch the RPM of the helicopters head. Up
to 3 rates can be set for each condition.
*The governor is used by connecting the governor speed
setting channel to CH7 (initial setting).
*When using an independent governor [ON]/[OFF] switch,
connect the AUX([ON]/[OFF]) connector of the governor to
CH8 (initial setting) and set the switch to CH8 (Governor2)
at the Function menu of the Linkage Menu.
*When using the Fuel Mixture function, the mixture servo
is controlled from the governor. When transmitting the
mixture curve data from the transmitter to the governor, the
governor AUX (m.trm) connector must be connected to CH8
(initial setting) and governor side setting performed. See the
governor instruction manual.
Note:Alwaysset(Control)and(Trim)to[--]for
[Governor]and[Governor2]oftheFunctionmenu
oftheLinkagemenu.
●Select[GOVERNOR]atthemodelmenu
andcallthesetupscreenshownbelow
bytouchingtheRTNbutton.
(Currently selected condition name)
●FinetuningVRsettings
●RPMadjustment
●Unitdisplayselection:
[%]/[rpm]
Setting method
●Activate the mixing
Whenusingthisfunction,movethecursorto
the[INH]itemandtouchtheRTNbuttonto
switchtothedatainputmode.
SelecttheACTmodebyscrollingthetouch
sensor.
*The display blinks.
TouchtheRTNbuttontoactivatethemixing
andreturntothecursormode.(ONis
displayed.)
 
WhentheGovernorischangedfromthe
defaultinhibited(INH)statetotheactive
(ACT)state,theendpointmenuwillbe
displayedanditispossibletoutilizethe
endpointsforthisgivencondition.
*When the function is set ON/OFF at the governor setup
screen, the governor rpm setting channel end point servo
travel and limit point are now initialized.
*When changed from INH to ACT (ON), the servo travel is
initialized to 100 and the limit point is initialized to 155.
*When operation is changed to INH at all conditions, the
servo travel is initialized to 100 and the limit point is
initialized to 135.
●RPM adjustment
Movethecursortotherateitemandtouch
theRTNbuttontoswitchtothedatainput
mode.
Adjusttherpmbyscrollingthetouchsensor.
Initialvalue:50%(1500rpm)
Adjustmentrange:OFF,0~110%(OFF,
700~3500rpm)
*When the RTN button is touched for one second, the
sensitivity is reset to the initial value.)
TouchtheRTNbuttontoreturntothecursor
mode.
●Unit diplay selection
MovethecursortotheUNITitemandtouch
theRTNbuttontoswitchtothedatainput
mode.Selecttheunitbyscrollingthetouch
sensor.
TouchtheRTNbuttontochangethe
operationmodeandreturntothecursor
mode.
Scrolling
●Movingcursor
●Selectingmode
●Adjustingvalue
●Tonextpage