M200 Handheld OTDR User’s Guide Test & Inspection
Limited Warranty One Year Limited Warranty All Noyes products are warranted against defective material and workmanship for a period of one year from the date of shipment to the original customer. Any product found to be defective within the warranty period will be repaired or replaced by Noyes. In no case will Noyes liabilities exceed the original purchase price of the product.
Table of Contents Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Getting Started: M200 Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Getting Started: Display Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Set-up: General Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Home Page: Changing the Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety Information WARNING! Use of procedures or adjustments other than those specified herein may result in hazardous radiation exposure. 850/1300 nm multimode OTDR port This is a CLASS I LASER output 1310/1550 nm This is a CLASS I LASER output single-mode OTDR port VFL port This is a CLASS II LASER output. Do not stare into beam WARNING! Do not connect the OTDR to any fiber that is not dark, or that is terminated by a device with reflectivity > -13 dB.
Getting Started: M200 Keys The use of each key is summarized in the table below. Key Symbol Key Name Key Function Power Press and hold (approx. 1 sec.) to turn the M200 on or off. VFL laser ON 2Hz - Press and hold (approx. 2 sec.) LED will flash ON CW - Press and hold (approx. 4 sec.) LED will be solid OFF - Press and hold (approx. 1 sec.) LED should be OFF Menu Press to access the Main Menu. Left and Right Tab keys Press to display the next/previous available Menu Tab or View Tab.
Getting Started: Display Features Charging battery icon is displayed when the AC adapter charger is connected to the M200 Main Menu tabs Menu area Battery icon - fully charged Test Viewer tabs Page header Soft key labels Results area Menu View 6 Trace View
Set-up: General Settings Keys used Key Symbol Key Name Left & Right Tab Key Function Scroll through menu tabs to display [General] Up & Down Arrows Navigate up/down the list of parameters Left & Right Arrows Display available options Select Display a submenu or editor Back Return the previous menu Press Left / Right arrow key to select units of measure Press Left / Right arrow key to toggle the Beeper function Press [Select] key to display submenu, which allows setting Date Press [Select] key
Home Page: Changing the Mode Keys used Key Symbol Key Name Left & Right Arrows Key Function Scroll through modes Page name Battery status icon Current Test Mode Press the Left or Right arrow key to select a test mode Current Test Port Launch Cable icon is shown if a Launch Cable is used Receive Cable icon is shown if a Receive Cable is used Fiber name+number Press the Up or Down arrow key to increase or decrease the displayed fiber number Current folder Press to display the File Manager Press t
Set-Up: Full Auto Mode Settings Definitions Core Settings Full Auto Mode settings are common for all OTDR Test Modes and will be referred to as Core Settings. Launch Cable (Launch Cord) A test cable used to connect the OTDR to the near end of the link under test that is long enough to allow the OTDR to measure the loss of the first connection.
Set-Up: Live Mode Settings In addition to Core Settings, the Live mode allows you to set the Wavelength and Range parameters. Choose a wavelength for your test port selected Press the Left / Right arrow key to display the desired value Set-up: Expert Mode Settings In addition to Core Settings (Full Auto Mode settings), the Expert test mode allows you to set the Wavelength, Range, Pulse Width, Averaging Time, Filter parameters.
Set-up: Expert - Manual Setup Note: The Range, Pulse Width, and Averaging Time parameters are user-selectable if the [Setup] parameter is set to [Manual]. Range The [Range] parameter determines the distance range of the full (unzoomed) trace. It also determines [Resolution] - the distance between data points in the trace: the longer the range, the wider the data point spacing. We recommend selecting the shortest distance range that is longer than the fiber under test.
File Manager File Manager is accessed from the File tab > [Folder...] parameter in Main Menu settings, or from the Home page by using the [Files] soft key. Use to change folders and go between CF, USB, and Internal storage. Use Tools within the File Manager to create, delete, copy and move files and folders.
Opening a Trace File for Review Access File Manager from the Home Page by pressing the [Files] soft key Press to open a trace for review [Files] soft key Saving a File Save After completing a test press Save key to save file in current folder with name established in the set up process. Save-As To change the folder or file name after a test has been completed, go to the File tab and make changes. Once satisfied press the save key.
Set-up: File Menu Settings Set Folder/ File name and Folder location where the next trace file will be saved.
Running Tests & Viewing Results Test Press to start Test M200 header will be [Testing] Test Press to stop Test M200 header will be [Stopped] When test is done, [Not Saved] is the M200 header After test is saved, [Saved] is the M200 header Page Tabs (keys used Page icon Page name ) Description Trace Page Displays OTDR trace, setup, A/B cursors, Loss and Distance between A & B cursors Event Page Displays OTDR trace, Event location, type, reflectance and insertion loss Summary Page Displays OTDR tra
Trace Page Features 8 9 7 6 10 1 2 Active cursor is bold [B], inactive cursor is dashed [A] 3 4 5 For dual-wave tests, press to toggle the displayed test results Distance block of active cursor is highlighted Key definitions Horizontal Zoom ( ) A/B cursor select Move cursor Move cursor Left Right Horizontal Zoom ( ) 16
Trace Page Features Trace Page Features Ref Feature Description 1 Trace This is a graph of insertion loss vs. distance. The vertical axis shows loss in dB. The horizontal axis shows distance in user-selected Distance units. 2 Cursors Used to measure loss, and distance. The active cursor can be moved by pressing either Left [ ] or Right [ ] arrow key. Press the -[Select] key to toggle between the A and B cursors.
Zoom Adjust View Zoom Adjust View Active cursor Press to Unzoon/ Rezoom Unzoom Rezoom Keys definitions Vertical Zoom ( ) A/B cursor select Horizontal Zoom ( ) Horizontal Zoom ( ) Vertical Zoom ( ) 18
Event Table & Summary Results Event Table & Summary Results are generated together 1 Set Mode to Full Auto or set Mode to Expert and Events (Events menu) to Auto. 2 In the Event Table or Summary Page, press the [Calc] soft key if no Event Table or Summary Page was created. Or press the [Re-Calc] soft key to generate a new Event Table or Summary Page if you changed the GIR or BC.
Fault Locating: Full Auto Set Mode to Full Auto Select Launch Cable: Noyes (150m), None, User Clean and Connect launch cable In General Tab Set Distance Units: m, ft, kft, km, mi Select Test Port: MM or SM Press Test key Select Fiber Type Trace displaying Fault Expected trace Launch Cable Break Two Point A/B Measurement Measuring Loss on an OTDR Trace An OTDR trace shows relative power vs. distance.
Text Editor Editable text field Touch Pad of alphanumeric characters (Tap with stylus or use Arrow and Select keys) Press when done Soft key labels Numerical Editor Parameter name Editable numeric field Selection cursor Numeric Touch Pad (Tap with stylus or use Arrow and Select keys) Press when done 21
Transferring Files From M200 via USB Function port to PC To transfer files from your M200 to a PC using a USB cable, perform the following: 1 Connect your M200 to a PC using a type A to Mini USB B cable. If your PC requests new USB drivers, install the CD-ROM that comes with your M200, which should contain the needed drivers. This step only needs to be performed the first time you connect your M200 and PC together.
Specifications OTDR Specifications Multimode Single-mode Emitter Type Laser Safety Class Class 1 FDA 21 CFR 1040.0 & 1040.11 Center Wavelengths 850/1300 nm 1310/1550 nm Wavelength Tolerance ± 20 / ± 30 nm ± 20 / ± 30 nm Dynamic Range (SNR = 1) 22 dB 26 dB Event Dead Zone 1.5 m 1.
Recommended Accessories You will need fiber optic test jumpers to connect your M200 to the fiber under test. Test jumpers must have the same core and cladding size as the fiber under test. The connector at one end of the test cable must mate with the appropriate optical port on the M200. The connector on the other end must mate with the fiber optic link under test.
Cleaning Tips Clean Test Cables and FUT Connector end faces must be kept free from dirt or other contaminates to ensure accurate measurements and operation. It is important to keep connectors on the launch and receive cables and those on the Fiber Under Test (FUT) clean. Follow your company’s approved cleaning procedures. Cleaning the Optical Ports CAUTION! Before conducting the following procedures be sure to have the M200 turned OFF.
FAQs Can I save traces for viewing later? Yes. There is a dedicated Save key. In the Main Menu “File Tab”, set up the location/ folder (Internal, CF, or USB) to save the file, the file naming format and fiber number. The fiber number will increment after each trace is saved. Tips Expert OTDR Setup RANGE: Length • Too Short: you will not capture the entire fiber length • Too Long: trace will be squashed to left side of Screen • Good Range: 1.
Recharging Batteries Repair and Calibration You may charge the batteries while the M200 is switched on or off by attaching an AC power adapter. Unauthorized repair of the Noyes test equipment will void the warranty. • Plug the AC adapter/charger into a standard wall outlet. • Connect the AC adapter/charger to the Power port located on the M200 side panel. • The [AC/Charger] indicator on the side panel will turn on- Red • Charge batteries until the [AC/Charger] indicator turns Green.
Thank you for choosing Noyes Test & Inspection 16 Eastgate Park Road . /9 % 3 Belmont, NH 03220 )3/ Phone: 800-321-5298 # % 24 ) & ) % $ 603-528-7780 Fax: 603-528-2025 www.AFLtele.