DIGITAL CAMERA XF56mmF1.2 R SIMPLE MANUAL -For Repair Centers without the Lens Repair Training- WARNING z THE COMPONENTS IDENTIFIED WITH THE MARK “ AND THE PARTS LIST ARE CRITICAL FOR SAFETY. ” IN THE SCHEMATIC DIAGRAM z REPLACE THOSE COMPONENTS ONLY WITH THE COMPONENTS SPECIFIED IN THE SCHEMATIC DIAGRAM AND THE PARTS LIST. z IF YOU USE PARTS NOT SPECIFIED, IT CAN RESULT IN A FIRE AND AN ELECTRICAL SHOCK. Ref.No.
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- SAFETY CHECK-OUT During repair and safety checking, conduct the followings. 1. Check if there are unsoldered or poorly soldered connections. Check the entire board surface for solder splasher and bridges. CAUTION: FOR PROTECTION AGAINST FIRE HAZARD, REPLACE ONLY WITH SAME TYPE 2.5 AMPERES 125V/250V FUSE. 7. 2.
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- CONTENTS 1. List of Jigs······································································································ 4 2. Inspection······································································································· 5 3. Parts List ······································································································· 13 4.
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- 1. List of Jigs 1-1. Inspection Parts No. ---- FZ09206-100 or FZ09206-200 or FZ09206-300 Name Image FUJIFILM X-Pro1 Comment • MAIN PWB Initialize • LENS Repair Firmware Ver3.45 Download • Lens Set Serial • LENS Firmware Update • Resolution Inspection Remarks Standard camera Prepare the product. * Do not use the user's X-Pro1 camera body for lens repair.
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- 2. Inspection 2-1. Inspection and Factory Settings Sequence 1 Item Mode Appearance check Preparations for adjustment (measurement points, subject, other) (1) Check lens visually and by touching.
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- Sequence 5 Item Mode Aperture operation A(Aperture check Priority) Preparations for adjustment (measurement points, subject, other) (1) Turn the Aperture ring. Method of adjustment (VRs, waveforms, required values) (1) Check if there is no abnormal Measuring equipment and jigs Standard noise. camera Check if the zoom moves X-Pro1 smoothly.
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- 2-2. Lens Dust Check (1) Prepare a DUST CHART (ZJ01898-100) or DUST CHART2 (ZJ01899-100). (2) Wiped off dusts of lens surface. (3) Compared to “DUST CHART”, measure the sizes of dusts. (4) Determine pass or fail referring to Figure. 1 and Table 1. A B D/2 D Figure. 1 [Specification of front lens] 0.15mm or less ~ 0.1mm or more Less than 0.
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- 2-3.
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training [Settings for Resolution Inspection] (1) Cut XF60 CIPA Resolution Chart (ZJ02018100) like figure 2, and stick it on a Gray Chart of 917mm X 606.9mm. (2) Referring to figure 1 on the right, prepare a camera and the resolution chart.
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training [Resolution Inspection] (1) Download the software from the WEB and install the software to the PC. We have uploaded the “XF56MM RESOLUTION CHECK SOFTWARE (ZJ02286-100.zip)” on our website: (https://cs-support-eid.fujifilm.co.jp). (2) Decompress the “ZIP type” file of “ZJ02286-100”. (3) Copy the “FFRes_XF56mm” folder to the “C” drive on the PC.
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training(9) The center of the chart will appear. The chart and values determined by [Center resolution analysis] are displayed. By pressing the [Enter] key, the measurement continues in the order of “upper left” → “lower left” →”upper right” → “lower right”. Green lines indicate the measured resolution determined by the software.
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training(10) The measurement has been completed once “OK” is displayed for all of [Resolution measurement]. [Completing Resolution Inspection] Center H: 2,500 lines or more Center V: 2,500 lines or more Periphery H: 1,500 lines or more Periphery V: 1,500 lines or more • If failed, conduct shooting 3 times. If one image at least meets the criteria, it will be OK.
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- 3. Parts List 3-1. Packing and Accessories A111 A113 A112 A104 A108 A109 A105 A103 A107 A101 A110 A106 13 A102 Ref No. A101 A102 A103 A104 A105 Parts No.
Confidential: FUJIFILM Service Center Use Only XF56mmF1.
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- 4. Appendix 4-1. List of Related Technical Updates Issued To ensure that after-sales service is performed accurately, keep a record here of the technical updates issued that cover this device. Technical Update No.
Confidential: FUJIFILM Service Center Use Only FinePix JX420 / JX430 Service Manual Midtown West, 7-3, Akasaka 9-chome, Minato-ku, Tokyo 107-0052, Japan 2