Appropriate Measures
Solution : Replacing the harbness connected DTU, if it still has the problem, replace the DTU board
Measures : Check the operation by replacing the harbness connected DTU or DTU board.
(10) DTU Link Fail (MHU, ROU)
Phenomenon
Alarm window : GREEN → RED
Causes
Occur the problems of link fail between DTU board and CPU
Appropriate Measures
Solution : Check Reference clock or Check the connectivity between DTU board and Back Board
Measures : Check the connectivity status of DTU board and replace DTU board.
(11) VSWR (ROU)
Phenomenon
Alarm window : GREEN → RED
Causes
Occur the problems at antenna input port or AMP
Appropriate Measures
Solution : Check antenna inputport connection status, if there is no fault, replace the AMP
Measures : Check the antenna input port and if there is no fault, replace the AMP and confirm it works.
(12) Over Power (ROU)
Phenomenon
Alarm window : GREEN → RED
Causes
Has the problem at RRFU intergrated module output
Appropriate Measures
Solution : Although it set the static output by controling ATT, if it still has the problem, RRFU intergrated
moduled should be replaced
Measures : Check the operation by chekcing and repacing the RRFU intergrated module
(13) Over Temp (ROU)
Phenomenon
Alarm window : GREEN → RED
Causes
RRFU’s intergrated module temparature is more than 85
Appropriate Measures
Solution : Checm the temparatrue table. Even though it is set approprate temarature, still has a problem. APD
AMP should be replaced.
Measures : Check the operation by replacing the RRFU intergrated module
(14) Battery (ROU)
Phenomenon
Alarm window : GREEN → RED
Causes
Battery has some problems.