Installation Instructions

2
30” ELECTRIC FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
1. Clearances and Dimensions
a. Provide adequate clearances between the range and adjacent combustible surfaces.
b. Location—Check location where the range will be installed. Check for proper electrical supply and the stability of oor.
c. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must be
solid and level.
BACK
VIEW
1”
30” Minimum*
Minimum to
wall on either
side of range
above 36” height.
36”
18”
Minimum to
cabinets on
either side
of range
25” Max.
13”
Maximum depth
for cabinets
above range top.
0” clearance below cooking top and at rear of range
Typical cabinet installationFront
view
Side
view
30”
Minimum
30”
Minimum
FRONT
VIEW
Minimum to wall
on either side of
range above
36’(914 mm)
height.
SIDE
VIEW
1”
(25 mm)
36”
(914 mm)
30”
(762 mm)
Minimum
30”
(762 mm)
18”
(457 mm)
Minimum to
cabinets on
either side of
range.
13”
330 mm
Maximum depth
for cabinets
above range top.
0” (0 mm) clearance below cooking top and at rear of range.
30”
(762 mm)
RANGE
OVERALL
DIMENSIONS
30”
(762 mm)
25- 3/4”
(654 mm)
48”
(1219 mm)
Maximum
49”
(1245 mm)
Maximum
Door Open
29- 7/8”
(759 mm)
36
1/8”
Centerline of
range
All dimensions for electrical outlet location
are maximum.
Dashed cubed area
shows where the electrical outlet must be
installed
for flush to the wall installation.
25”
635 mm
11
(279 mm)
22”
(559 mm)
Wall
Edge
2-5/8” (67 mm) for models
equipped with warmer drawers
3-1/2” (89 mm) for models
equipped with storage drawers
6”
(152 mm)
(3 mm)
(914 mm)
*30" (762 mm) MINIMUM CLEARANCE BETWEEN THE
TOP OF THE COOKING SURFACE AND THE BOTTOM
OF AN UNPROTECTED WOOD OR METAL CABINET; OR
24" (610 mm) MINIMUM WHEN BOTTOM OF WOOD OR
METAL CABINET IS PROTECTED BY NOT LESS THAN
1/4" (6 mm) FLAME RETARDANT MILLBOARD COVERED
WITH NOT LESS THAN NO. 28 MSG SHEET STEEL, 0.015"
(0.4 mm) STAINLESS STEEL, 0.024" (0.6 mm) ALUMINUM
OR 0.020" (0.5 mm) COPPER. 0" (0 mm) CLEARANCE IS
THE MINIMUM FOR THE REAR OF THE RANGE. FOLLOW
ALL DIMENSION REQUIREMENTS PROVIDED ABOVE
TO PREVENT PROPERTY DAMAGE, POTENTIAL FIRE
HAZARD, AND INCORRECT COUNTERTOP AND CABINET
CUTS.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY
REACHING OVER HEATED SURFACE UNITS, CABINET
STORAGE SPACE LOCATED ABOVE THE SURFACE UNITS
SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE
PROVIDED, THE RISK CAN BE REDUCED BY INSTALLING
A RANGE HOOD THAT PROJECTS HORIZONTALLY A
MINIMUM OF 5" (127 mm) BEYOND THE BOTTOM OF
THE CABINETS.
29
7
/
8
"
Maximum
36
5
/
8
"
±
1
/
4
"
26
6
/
8
"
47"
Door open
Fig. 2
Fig. 1
Fig. 3