Top Load Laundry - Gas Dryer
Frigidaire Baseline (S Models)
Front
38
1
/2"
44
1
/4"
12
1
/8"14
7
/8"
Rear vent
3
3
/4"
Recess or Closet Installation
Dryer installation requires 1" minimum installation
clearance on each side of unit and 6" minimum at
back. To acheive 6" minimum rear clearance, dryer
MUST use 90° quick-turn vent elbow. Closet
installation requires 2"
minimum clearance between
front of unit and vented door. Door MUST be vented
with 120 sq.
in. minimum louvered opening, equally
divided, located 3" from top and bottom of door.
A louvered door with equivalent air openings for
full-length of door is acceptable. Air openings
MUST remain unobstructed with door installed.
For additional installation details, refer to
Product Installation Guide on web.
30
13
/16"
48
5
/8"
Side
Vented door
6"
min. 2"
min.
Side
60"
sq.
in.
min.
3"
60"
sq.
in.
min.
3"
1"
min. 1"
min.
24"
min.
Front
Reversible
Door Swing
27"
120V Power cord
(rear) - 67" long
5
1
/8"
2
5
/8"
Gas supply pipe (rear)
FFRG4120S 02/17 © 2017 Electrolux Home Products, Inc.
Top Load Dryer Specifications
Product Shipping Weight (approx.) – 143 Lbs.
Designed for HOME USE only, not recommended for commercial
application.
An electrical supply with grounded three-prong receptacle is
required. The power supply circuit must be installed in accordance
with current edition of National Electrical Code (ANSI/NFPA 70)
and local codes & ordinances. (Do not use same circuit as washer.)
Voltage Rating – 120V / 60 
Amps @ 120 Volts = 9.0 Amps
Connected Load (kW Rating) @ 120 Volts = 4.0 kW
Equipped with 120V 3-wire power supply cord, approx. 67" long.
Always consult local and national electric & gas codes.
Dryer installation requires 1" minimum installation clearance on
each side of unit and 6" minimum at back. To acheive 6" minimum
rear clearance, dryer MUST use 90° quick-turn vent elbow. Closet
installation requires 2" minimum clearance between front of unit
and vented door. Door MUST be vented with 120 sq. in. minimum
louvered opening, equally divided, located 3" from top and bottom
of door. A louvered door with equivalent air openings for full-length
of door is acceptable. Air openings MUST remain unobstructed with
door installed. (For additional installation details, refer to Product
Installation Guide on web.)
Do NOT install in area exposed to dripping water or outdoor weather
conditions; where gasoline or other flammables are kept or stored; or
where dryer comes in contact with curtains, drapes or anything that
will obstruct flow of combustion and ventilation air.
For garage installation, dryer MUST be located minimum 18" above floor.
Floor MUST be solid with 1" maximum slope. Do NOT install on
carpeted surface.
Dryer MUST exhaust to outside of building, NOT into any concealed
space.
Exhaust installation requires minimum 4"-diameter rigid or semi-rigid
metal duct with approved, unobstructed vent hood having swing-out
damper(s). If installing rigid metal duct (preferred), do not exceed
MAXIMUM venting run length of 64 ft., allow deductions for elbows
and vents. If installing semi-rigid metal duct, do not exceed MAXIMUM
venting run length of 8 ft., always allow deductions for elbows and
vents (Refer to Product Installation Guide on web for additional
information). Do NOT use flexible plastic or metal foil duct and use
shortest run possible.
Gas supply line should be 1/2" black iron, stainless steel, or plastic-
coated brass pipe and MUST have individual shutoff valve, located
within 6 feet of dryer. Gas supply line must be installed in accordance
with current edition of National Fuel Gas Code (ANSI Z223.1) and
local codes & ordinances.
Leveling legs supplied to level dryer properly and reduce excessive
noise and vibration.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
LP Gas Conversion Kit – (PN # HA004).
Drying Rack – (PN # 137067300).
Dryer
FFRG4120SW 6.7 Cu. Ft. D.O.E. Gas