Use & Care Guide
7
OPERATING INSTRUCTIONS
Status Window
The STATUS window, available on some models, indicates the following activity:
1-24............. Number of delay start
hours. The last hour
will count down in
minutes.
L0----L6............ Level of Rinse Aid
dosage.
Displayed
Error Code*
Problem
Solution
i10
A low fi ll has been
detected.
Look for a pinched water supply line, or water shutoff is
not completely opened.
i20;
i40;
iF0
Clogged fi lters or a
restricted drain line
has been detected.
Check and clean both fi lters and sump area and check
for a pinched or blocked drain hose. If the drain line is
attached to a disposer, check that the knockout plug has
been removed.
i30
A leak or overfl ow
of water has been
detected in the
bottom pan.
Look for loose connections at the water inlet valve and
ensure the unit is properly leveled.
i50 A problem has been
detected with the
drain or wash motor.
i60
A problem has been
detected with the
water heating system.
iC0
A problem has been
detected with the
electronic control
system.
Pressing the cancel button or turning power off at the
breaker for 5 min. should clear this error code and the
unit can be restarted.
If this does not resolve the problem, service
will need to be called.
*In all Error Code instances, if Pressing the cancel button or turning power off at the breaker for 5
min. does not resolve the problem, contact the Frigidaire Customer Care Center at 1-800-944-9044.
Instruction
Code
Displayed
Problem
Solution
Close door
This indicates the
door has been left
open or not properly
latched.
Ensuring the door is properly latched will clear the display.
This does not indicate a problem with your dishwasher
and service will not need to be contacted.
MINUTES.......... Number of minutes
left in cycle (1-199).
U s e r I n s t r u c t i o n C o d e
E r r o r C o d e
CLOSE DOOR.......... Close door will scroll
across the status
window indicating the
door needs to be
closed.
PRESS START.......... Press start will scroll
across the status
window indicating the
START/CANCEL pad
needs to be pressed.