Manual

Front Panel
Chassis
Accessory
Wall Sleeve
Accessory
Outdoor Grille
Wall Sleeve
Adapter
PTAC - Heat Pump and Electric Heat models_Prod Specs
Rearward Slope
Outside Wall
1/4
" Slope
Inside Wall
Specifications
subject to change.
Plug Type (NEMA)
6-20P
Product Dimensions
Height
Width
Depth
Max. Wall Thickness
Manufacturer Wall Sleeve Part Number
General Electric
Amana
Trane
Friedrich
16"
42"
13-13/16"
13-13/16"
Metal Sleeve RAB71
Plastic Sleeve RAB77
Metal Sleeve WS900B
Metal Sleeve SLV149
T-Series Metal 11-1/2-in. Deep
Wall Sleeve
Standard-Depth Wall Sleeve
16 X 42 X 13-3/4-in. PXWS
Wall Cutout Dimensions
Height
Width
16-5/16"
42-3/16"
PTAC Specifications
Product Shipping Weight (approx.) – 126 Lbs.
An electrical supply with grounded three-prong receptacle is required.
The power supply circuit must be installed in accordance with current
edition of National Electrical Code (ANSI/NFPA 70)
and local codes & ordinances.
Voltage Rating 230V / 208V / 60 Hz / 20 Amps
Amps @ 230/208V Volts =
(Cool) 2.8 / 3.0 Amps / (Electric Heater) 13.2 / 12.2 Amps
Always consult local and national electric codes.
Recommended Circuit Breaker – 20 Amps
Unit equipped with 230/208V 3-wire power supply cord, NEMA plug
type 6-20P, approximately 66" long.
In order for condensate water to drain properly inside the unit, the
sleeve must be installed properly: Level from right to left with a slight
1/4" rearward pitch from the indoor side to the outdoor side as shown in
the illustration above. Refer to the Installation Instructions on the web.
The drain kit listed on the Frigidaire® PTAC Accessories page can
be used for an internal or external drain. This applies to new and
replacement installation.
New Installation
For new installation, Frigidaire® PTAC Sleeves are available and
recommended for proper installation. See accessories pages for
sleeve options.*
Standard PTAC installation requires 13-13/16" maximum wall thickness,
unless a wall sleeve is used.
If the PTAC unit protrudes more than 4", then it is suggested that it be
installed with a subbase. See accessories pages for subbase options.
Replacement Installation
When replacing existing PTAC with new unit, refer to Product
Installation Guide on web to identify existing wall-sleeve manufacturer
and size compatibility. If proper installation and slope are suspect,
then correct installation of Frigidaire® PTAC Sleeve options
recommended.
For any sleeve retrofit application, be sure that the foam seals
(factory-installed on the tube sheets) provide a good seal between
the grille and the outdoor coil tube sheets. These foam seals provide
a barrier that stops air from the inside mixing with air on the outside
(known as air recirculation).
Using Frigidaire® wall sleeve with Non-Frigidaire grille requires
installation of an Accessory Baffle Kit, which ensures a good seal
between the unit and exterior grille to prevent air recirculation. Air
recirculation is a large contributor to performance loss and premature
damage to major components.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
*See Frigidaire® PTAC accessories pages attached for optional accessories.
USA
10200 David Taylor Drive
Charlotte, NC 28262
1-866-942-1567
frigidaire.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-866-942-1567
frigidaire.ca
FRP77ETT2A 08/11 © 2011 Electrolux Home Products, Inc. Printed in the U.S.A.
Packaged Terminal Air Conditioner (PTAC)
FRP77ETT2A Air Conditioner / Electric Heater