Manual
Front Panel
Chassis
Accessory
Wall Sleeve
Accessory
Outdoor Grille
Wall Sleeve
Adapter
PTAC - Heat Pump and Electric Heat models_Prod Specs
Rearward Slope
Outside Wall
1/4
" Slope
Inside Wall
Specifications
subject to change.
Plug Type (NEMA)
6-20P
Product Dimensions
Height
Width
Depth
Max. Wall Thickness
Manufacturer Wall Sleeve Part Number
General Electric
Amana
Trane
Friedrich
16"
42"
13-13/16"
13-13/16"
Metal Sleeve RAB71
Plastic Sleeve RAB77
Metal Sleeve WS900B
Metal Sleeve SLV149
T-Series Metal 11-1/2-in. Deep
Wall Sleeve
Standard-Depth Wall Sleeve
16 X 42 X 13-3/4-in. PXWS
Wall Cutout Dimensions
Height
Width
16-5/16"
42-3/16"
PTAC Specifications
•
Product Shipping Weight (approx.) – 126 Lbs.
•
An electrical supply with grounded three-prong receptacle is required.
The power supply circuit must be installed in accordance with current
edition of National Electrical Code (ANSI/NFPA 70)
and local codes & ordinances.
•
Voltage Rating – 230V / 208V / 60 Hz / 20 Amps
•
Amps @ 230/208V Volts =
(Cool) 2.8 / 3.0 Amps / (Electric Heater) 13.2 / 12.2 Amps
•
Always consult local and national electric codes.
•
Recommended Circuit Breaker – 20 Amps
•
Unit equipped with 230/208V 3-wire power supply cord, NEMA plug
type 6-20P, approximately 66" long.
•
In order for condensate water to drain properly inside the unit, the
sleeve must be installed properly: Level from right to left with a slight
1/4" rearward pitch from the indoor side to the outdoor side as shown in
the illustration above. Refer to the Installation Instructions on the web.
•
The drain kit listed on the Frigidaire® PTAC Accessories page can
be used for an internal or external drain. This applies to new and
replacement installation.
New Installation
•
For new installation, Frigidaire® PTAC Sleeves are available and
recommended for proper installation. See accessories pages for
sleeve options.*
•
Standard PTAC installation requires 13-13/16" maximum wall thickness,
unless a wall sleeve is used.
•
If the PTAC unit protrudes more than 4", then it is suggested that it be
installed with a subbase. See accessories pages for subbase options.
Replacement Installation
•
When replacing existing PTAC with new unit, refer to Product
Installation Guide on web to identify existing wall-sleeve manufacturer
and size compatibility. If proper installation and slope are suspect,
then correct installation of Frigidaire® PTAC Sleeve options
recommended.
•
For any sleeve retrofit application, be sure that the foam seals
(factory-installed on the tube sheets) provide a good seal between
the grille and the outdoor coil tube sheets. These foam seals provide
a barrier that stops air from the inside mixing with air on the outside
(known as air recirculation).
•
Using Frigidaire® wall sleeve with Non-Frigidaire grille requires
installation of an Accessory Baffle Kit, which ensures a good seal
between the unit and exterior grille to prevent air recirculation. Air
recirculation is a large contributor to performance loss and premature
damage to major components.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
*See Frigidaire® PTAC accessories pages attached for optional accessories.
USA
•
10200 David Taylor Drive
•
Charlotte, NC 28262
•
1-866-942-1567
•
frigidaire.com
CANADA
•
5855 Terry Fox Way
•
Mississauga, ON L5V 3E4
•
1-866-942-1567
•
frigidaire.ca
FRP77ETT2A 08/11 © 2011 Electrolux Home Products, Inc. Printed in the U.S.A.
Packaged Terminal Air Conditioner (PTAC)
FRP77ETT2A Air Conditioner / Electric Heater