Gas Installation

5
30" GAS RANGE INSTALLATION INSTRUCTIONS
2
Provide an adequate Gas Supply
When shipped from the factory, this unit is designed
to operate on 4" (10,16cm) water column (1.0 kPa)
Natural gas manifold pressure. A convertible pressure
regulator is connected to the range manifold and
MUST be connected in series with the gas supply line.
If LP/Propane conversion kit has been used, follow
instructions provided with the kit for converting the
pressure regulator to LP/Propane use.
Care must be taken during installation of range not to
obstruct the ow of combustion and ventilation air.
For proper operation, the maximum inlet pressure to
the regulator should be no more than 14" (35,56cm)
of water column pressure (3.5 kPa). The inlet
pressure to the regulator must be at least 1" (.25
kPa) greater than the regulator manifold pressure
setting. Examples: If regulator is set for natural gas 4"
(10,16cm) manifold pressure, inlet pressure must be at
3
Seal the openings
Seal any openings in the oor under the range after
gas supply line is installed.
Recommended hole
location for through
the oor gas entry line.
NOTE: The gas entry
line hole can be also
placed anywhere in
the shaded area.
NOTE:
The electric outlet can
be placed anywhere in
the hatched area.
Recommended hole
location for through the
wall gas entry line.
Figure 5a
C. Level and position the range -
Slide range to
its nal position. Insert the range leveling leg in the
anti-tip bracket. Visually verify if the anti-tip bracket is
engaged. Lower the range by adjusting the 4 leveling legs
alternatively until the range is level. Check if the range
is level by placing a spirit level on the oven rack. Take 2
readings with the spirit level placed diagonally; take a
reading in one direction and then in the other direction.
Level the range if necessary by adjusting the leveling legs.
Figure 3
Figure 4
least 5" (12.60cm); if regulator has been converted for
LP/Propane gas 10" (25,4cm) manifold pressure, inlet
pressure must be at least 11" (27,9cm).
Leak testing of the appliance shall be conducted
according to the instructions in step 4H.
The gas supply line should be ½" or ¾" I.D.