Installation guide

ELECTRICAL CONNECTIONS
FOR A 3-WIRE SYSTEM
ELECTRIC Laundry Center
6. Attach the white (neutral) wire from the power cord and
the green ground wire from the appliance harness to the
silver-colored center terminal on the terminal block.
Tighten the screw securely.
1, Remove the screw securing the
terminal block access cover to
the rear panel and remove
cover.
2. Install a U.L approved strain
relief connector in the entry
hole on the back panel.
3. Insert a NEMA 10-30 Type SRDT, U.L approved power cord
through the strain relief.
4, Attach the power cord neutral (central wire) conductor to
the silver colored center terminal on the terminal block.
Tighten the screw securely.
/
5. Attach the remaining two power cord outer conductors to
the outer brass colored terminals on the terminal block.
Tighten both screws securely_
6. Tighten the screws securing the cord restraint firmly against
the power cord.
7_ Reinstall the terminal block accesscover.
ELECTRICAL CONNECTIONS
FOR A a-WIRE SYSTEM
ELECTRICLaundry Center
1
1. Remove the screw securing the
terminal block access cover to
the rear panel and remove
cover.
2. Install a U,L.approved strain
relief connector in the entry
hole on the back panel.
7
3. Remove the green neutral ground wire from the green
ground screw located above the terminal block.
4. Insert a NEMA 14-30 Type STor SRDT,U.L approved power
cord through the strain relief.
5. Attach the green power cord ground wire to the cabinet
with the green ground screw.
Gsc_wn Ground
Greei_
Con
(Cord)
Ground Red--
Wire
llver Terminal
erminal Block
Black
,White
7. Attach the red and black wires from the power cord to
the outer brass-colored terminals on the terminal block.
Tighten both screws securely.
8. Tighten the screws securing the cord restraint firmly
against the power cord.
9. Reinstall the terminal block access cover.
INSTALLATION
!. Run some water from the hot and cold faucets to flush
the water lines and remove particles that might clog up
the water valve screens.
2. Check inlet hoses to ensure the rubber washers are
installed in each end.
3. Carefully connect the inlet hoses to the water valve (on
the left side of the washer cabinet), tighten by hand, then
tighten another 2/3 turn with pliers,
4.
.
6.
_DO NOT CROSS THREAD OR
OVERTIGHTEN THESE CONNECTIONS.
Determine which water faucet is the HOT water faucet
and careful!v connect the bottom inlet hose to the HOT
vvate_ i_uce[, lighten by i_ano, iheri tighten anoiJiei 2/..
turn with pliers. Carefully connect the top inlet hose to
the COLD water faucet, tighten by hand, then tighten
another 2/3 turn with pliers.
_DO NOT CROSS THREAD OR
OVERTIGHTEN THESE CONNECTIONS, Turn the water
on and check for leaks at both connections.
Carefully move the laundry center to its final location.
To ensure the laundry center is level and solid on all four
legs, tilt the laundry center forward so the rear legs are
off the ground. Gently set the laundry center back down
to allow the rear legs to self adjust. Placea level on top of
the washer. Check it side to side, then front to back. Screw
the front leveling legs up or down to ensure the laundry
center is resting solid on all four legs (no rocking of the
laundry center should exist).
NOTE: Keep the leg extension at a minimum to prevent
excessive vibration.