Use and Care Manual
13
INSTALL RANGE HOOD
(Recirculating version)
Lift the range hood up under cabinet and determine
nal location by centering beneath cabinet. Mark on
the underside of cabinet the location of the 4 keyhole
mounting slots on the range hood (See slots
dimensions on page 6). Set range hood aside on a
covered surface.
Use ¹⁄8” (3 mm) drill bit and drill 4 pilot holes as shown.
NOTE: Make the drill holes on the thin area of the slot.
Install the 4 - .45 cm x 1.3 cm mounting screws in
pilot holes. Leave about ¼” (6.4 mm) space between
screw heads and cabinet to slide range hood into place.
Power Supply Cable Installation
For direct wire installations, run the home power
supply cable according to the National Electric Code
or CSA standards and local codes and ordinances.
There must be enough wiring from the fused disconnect
(or circuit breaker) box to make the connection in the
hood electrical terminal box.
NOTE
Do not reconnect power until the installation is
complete.
Remove the screw from the
terminal box cover.
Remove terminal box cover
and set aside.
1.
2.
3.
1.
2.
¹⁄4”
(6.4 mm)
A
A. Drill pilot hole
Remove the power supply knockout from the top
or rear of the vent hood (depending on the incoming
location of your home power supply cable) and
install a UL listed or CSA approved ½” strain relief.
Using 2 or more people, lift the hood into nal position.
Feed enough electrical wire through the ½” UL listed
or CSA approved strain relief to make connections in
the terminal box. Tighten the strain relief screws.
Position the range hood so that the large end of
the keyhole slots are over the mounting screws.
Then push the hood toward the wall so that the screws
are in the neck of the slots. Tighten the mounting screws,
making sure the screws are in the narrow neck of slots.
Recirculation Vent Cover
For installations which are recirculating the air exhaust,
the recirculation vent cover must be removed.
Remove the recirculating
vent cover by removing
the 2 mounting screws
with a phillips screwdriver.
NOTE: For installations
which are venting out
the roof or wall, the
recirculating vent cover
must remain in place.
Do not remove as unit
will not perform properly.
To complete the installation, go to “Make Electrical
Connection” section on page 12.
3.
4.
5.
Part being removed
A
A. Power supply
knockout
A. Terminal box cover
B. Screw
A
B
A
A. Keyhole slot
A
INSTALLING THE HOOD