Remove the power supply knockout from the top
or rear of the vent hood (depending on the incoming
location of your home power supply cable) and
install a UL listed or CSA approved ½” strain relief.
Using2ormorepeople,liftthehoodintonalposition.
Feed enough electrical wire through the ½” UL listed
or CSA approved strain relief to make connections in
theterminalbox.Tightenthestrainreliefscrews.
Position the range hood so that the large end of
the keyhole slots are over the mounting screws.
Then push the hood toward the wall so that the screws
are in the neck of the slots. Tighten the mounting screws,
making sure the screws are in the narrow neck of slots.
Recirculation Vent Cover
Forinstallationswhicharerecirculatingtheairexhaust,
the recirculation vent cover must be removed.
Remove the recirculating
vent cover by removing
the 2 mounting screws
with a phillips screwdriver.
NOTE: For installations
which are venting out
the roof or wall, the
recirculating vent cover
must remain in place.
Do not remove as unit
will not perform properly.
To complete the installation, go to “Make Electrical
Connection” section on page 11.
3.
4.
5.
RANGE HOOD USE
The range hood is designed to remove smoke, cooking
vapors and odors from the cooktop area. For best results,
start the hood before cooking and allow it to operate
several minutes after the cooking is complete to clear all
smoke and odors from the kitchen.
The hood controls are located on the top of the range hood.
Range Hood Controls
Operating the light
Push the light switch to the right to turn the light On.
Push the light switch to the left to the turn the light Off.
Operating the fan
Push the fan switch to the left for Low speed. Push the
fan switch to the right for High speed. Push the fan
switch to the middle for Off.
A. Incandescent light housing and cover
B. Charcoal filter retainer
C. Grease filter
A
C
B
A. On/Off light switch
B. Fan speed switch
A
B
woLnO
High
RANGE HOOD USE
Part being removed
A
A. Power supply
knockout