use & care Portable Air Conditioner Introduction...................................................... 2 Air Conditioner Features............................ 12 Important Safety Instructions.................... 3 Operating Instructions............................... 13 FCC Statement.................................................7 Care and Cleaning........................................ 22 Unit Description...............................................8 Before You Call............................
INTRODUCTION Welcome to our family Thank you for bringing Frigidaire into your home! We see your purchase as the beginning of a long relationship together. This manual is your resource for the use and care of your product. Please read it before using your appliance. Keep it handy for quick reference. If something doesn’t seem right, the troubleshooting section will help you with common issues. FAQs, helpful tips and videos, cleaning products, and kitchen and home accessories are available at www.
IMPORTANT SAFETY INSTRUCTIONS WARNING For Your Safety Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Read product labels for flammability and other warnings. WARNING Prevent Accidents To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following: • Be sure the electrical service is adequate for the model you have chosen.
IMPORTANT SAFETY INSTRUCTIONS SAFETY PRECAUTIONS DANGER! Avoid Serious Injury or Death • This air conditioner contains no user-serviceable parts. Always call an authorized Electrolux servicer for repairs. • Do not insert or place fingers or objects into the air discharge area in the front of the unit. • Do not start or stop the air conditioner by unplugging the power cord or turning off the power at the electrical box. • Do not cut or damage the power cord.
IMPORTANT SAFETY INSTRUCTIONS • Keep ventilation openings clear of obstruction. • The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance) and ignition sourcesor (for example:an operating electric heater) close to the appliance. • The appliance shall be stored so as to prevent mechanical damage from occurring.
IMPORTANT SAFETY INSTRUCTIONS corrode the copper pipe-work. NOTE Examples of leak detection fluids are – bubble method, – fluorescent method agents. If a leak is suspected, all naked flames shall be removed/extinguished. If a leakage of refrigerant is found contact local manufacter to replace unit. READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER. Unit must be upright for one hour prior to operating. The unit should be operated in a temperature range of 60°F - 95°F (16°C 35°C).
FCC STATEMENT FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
UNIT DESCRIPTION Explanation of symbols displayed on the unit This symbol shows that this appliance used a flammable WARNING refrigerant. If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire. CAUTION This symbol shows that the operation manual should be read carefully. CAUTION This symbol shows that a service personnel should be handling this equipment with reference to the installation manual.
ACCESSORIES INCLUDED & INSTALLATION INSTRUCTIONS 9 Accessories Included PARTS: PARTS NAME: QUANTITY: Window Kit Connector A 1 pc Exhaust hose connector B 1 pc Window Kit 1 set Exhaust Hose 1 pc Screws 4 pcs (1/2" screws) 2 pcs (3/4" screws) Safety Lock 1 pc Bolts 2 pcs Foam seal A 2 pcs Foam seal B 1 pc Remote Control 1 pc Battery 2 pcs Drain hose 1 pc Installation Instructions EXHAUSTING HOT AIR In the Cool Mode the appliance must be placed close to a window or opening so that
INSTALLATION INSTRUCTIONS 1. Extend either side of the hose(Fig.1). The hose can be extended from its original length of 15" up to 59", but try to maintain the minimum required length. Also make sure that the hose does not have any sharp bends or sags.(Fig.5) Fig.5 Extend the side of hose Fig.1A 2. Install the connector B into the unit (Fig.2). 1 Slide onto Installation in a double-hung sash window 2 Lock 1.
INSTALLATION INSTRUCTIONS 11 7.Cut the non-adhesive foam seal (B) to an appropriate length and seal the open gap between the top window sash and outer window sash, as shown in Fig.11. Cut this to fit your window Foam seal B Fig.8 3.Close the window sash securely against the window slider kit.(Fig.9) 4.Drive two 1/2" screws to secure the window slider kit to the window sash.(Fig.9) 5.Secure the window slider kit to the window sill(Fig.9): A: For wooden window: Use 3/4" screws for securing.
INSTALLATION INSTRUCTIONS & AIR CONDITIONER FEATURES 3.Close the window sash securely against the window slider kit.(Fig.14) 4.Drive two 1/2" screws to secure the window slider kit to the window sash.(Fig.14) 5.Drive two 3/4" screws to secure the window slider kit to the window sill.(Fig.14) Foam seal B Fig.15 Window slider kit window sill 3/4" screws 7.To secure sliding sash in place, attach right angle sash lock with 1/2" (12.7mm) screw as shown(Fig.16). 1/2" screws Fig.14 6.
OPERATING INSTRUCTIONS 13 OPERATING INSTRUCTION To change temperature setting Press the “ ” button to turn the unit ON. The unit will run in "Cool" mode with a set temperature of 72°F. Press the “ ” or “ ” button to choose the temperature in a range of 60°F - 90°F (16°C 32°C). Cool mode Press the “Mode” button until the Cool mode indicator lights up. Press the "fan speed" button to choose the fan speed according to the illumination of the fan speed indicator.
OPERATING INSTRUCTIONS Fan mode Press the “Mode” button until the Fan mode indicator lights up. In this mode, you can select fan speed “Lo”, “Med”, or “Hi”. In this mode, the “ ” or “ ” button is disabled and the screen displays the room temperature. Note: In this mode, the air exhaust hose does not need to be connected. Auto mode Press the “Mode” button until the Auto mode indicator lights up. Press the “ ” or “ ” button to choose the temperature you want.
OPERATING INSTRUCTIONS 15 Sleep mode When the unit is in Cool or Auto mode, you can press the “Sleep” button on remote control to make the unit run in Sleep mode. In this mode, the fan speed will automatically set to "Auto", which cannot be changed. In Cool mode the selected temperature will increase by 2 °F 30 minutes after the mode is selected. The temperature will then increase by another 2 °F for an additional 30 minutes.
OPERATING INSTRUCTIONS Child Lock Press and hold the Mode and “ ” button for 3 seconds to activate the Child Lock mode. In this mode, the unit’s setting cannot be changed by pressing the buttons on control panel. The display will show “LC” for 5 seconds then return to the normal display. Press and hold the Swing and Sleep button for another 3 seconds to quit this mode. Note: After the child lock feature activated the setting can still be changed by remote control or app.
OPERATING INSTRUCTIONS 17 Remote Control D C E B F A G H A Timer Button E on·off Button B Mode Button F Fan Speed Button C Temp/Timer Setting Button G Swing Button D Remote Control Screen H Sleep Button Battery Installation and Important Instructions Remove the cover at the back of the remote control. Insert the provided batteries correctly(see the instructions inside the battery compartment). Close up the cover. Fig.
OPERATING INSTRUCTIONS This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. How to Use the Remote Control Note: In this mode, the fan speed will be set as “low” automatically, which cannot be changed.
OPERATING INSTRUCTIONS cooling only models), or fan only operation depending on what temperature you have selected and the room temperature. The air conditioner will control room temperature automatically round the temperature point set by you. Note: In this mode, fan speed cannot be selected. Louver Swing Function 19 Sleep mode When the unit is in Cool, Heat or Auto mode, you can press the “sleep” button to make the unit run in Sleep mode.
OPERATING INSTRUCTIONS change delay shutdown timer at 0.5 hour increments up to 10 hours, then at 1 hour increments up to 24 hours. After 3 seconds, the timer function is enabled, then “off ” will stop flashing, the display will show the temperature and the control will count down the time remaining until shutdown. To cancel the setting, press the “timer” button again. You can also cancel the setting by pressing the “on·off” button.
OPERATING INSTRUCTIONS 21 Drainage Instructions Continuous Drainage During the Dry mode, you will need a garden hose (sold separately) to drain the condensate from the unit. Follow the steps below: • Unscrew the drain cap of continuous drain outlet(Fig.20). Drain cap for Dry mode Figure 20 • Connect one end of the garden hose (sold separately) to the drain outlet then lead the other end into a drain that is lower than the unit(Fig.21).
CARE AND CLEANING Cleaning Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards. CLEANING THE UNIT The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Never use harsh cleaners, wax or polish on the cabinet front. Be sure to wring excess water from the cloth before wiping around the controls.
BEFORE YOU CALL 23 Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance. OCCURRENCE SOLUTION • Wall plug disconnected. Push plug firmly into wall outlet. • Plug Current Device Tripped. Press the RESET button. Air conditioner will not operate. • House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.
BEFORE YOU CALL OCCURRENCE SOLUTION Room too cold. • Set temperature too low. Increase set temperature. Room too hot. • Set temperature too high. Lower setting. If These Solutions Fail, Call 1-800-944-9044(US)/1-800-265-8352(Canada) For Frigidaire Service.
MAJOR APPLIANCE LIMITED WARRANTY 25 Your appliance is covered by a limited one-year warranty for functional repairs only. For one year from your original date of purchase, Electrolux will pay all costs for repairing or replacing any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used and maintained in accordance with the provided instructions.
welcome home Our home is your home. Visit us if you need help with any of these things: owner support accessories service registration (See your registration card for more information.) Frigidaire.com 1-800-944-9044 Frigidaire.