Installation guide

30"
ELECTRIC
RANGE
INSTALLATION
INSTRUCTIONS
Direct Electrical
Connection
to
the
Circuit
Breaker,
Fuse
Box
or
Junction
Box
If
the
appliance
is
connected
directly
to
the
circuit
breaker,
fuse
box
or
junction
box,
use
flexible,
armored
or
nonmetallic
sheathed
copper
cable
(with
grounding
wire).
Supply
a
U.L.
listed
strain-relief
at
each
end
of
the
cable.
At
the
appliance
end,
the
cable
goes
through
the
Direct
Connection
Hole
(see
Figure
7)
on
the
Cord
Mounting
Plate.
Wire
sizes
(copper
wire
only)
and
connections
must
conform
to
the
rating
of
the
appliance.
Where
local
codes
permit
connecting
the
appliance-
grounding
conductor
to
the
neutral
(white)
wire
(see
Figure
8):
1.
Be
sure
that
no
power
is
supplied
on
the
cable
from
residence.
2.
Follow
instructions
on
previous
page
for
Four
Conductor
Wire
Connection
to
Range
(Fig.
7).
3.
In
the
circuit
breaker,
fuse box
or
junction
box
(Fig.
8):
a)
Connect
the
green
(or
bare
copper)
wire,
the
white
appliance
cable
wire,
and
the
neutral
(white)
wire
together.
b)
Connect
the
2
black
wires
together.
c)
Connect
the
2
red
wires
together.
Cable
from
Residence
Neutral
(white)
Wire
|
[ps
———
Junction
Box
aN
White
Wire
Green
U.L.-listed
Conduit
(or
Bare
Copper)
Connector
(or
CSA
Wire
Cable
from
_
listed)
Appliance
NOTE:
Be
sure
to
remove
the
supplied
grounding
strap.
—->
Figure
8
3-Wire
(Grounded
Neutral)
Electrical
System
(Example:
Junction
Box)
Where
local
codes
DO
NOT
permit
connecting
the
appliance-grounding
conductor
to
the
neutral
(white)
wire,
or
if
connecting
to
4-wire
electrical
system
(see
Figure
9):
1.
Be
sure
that
no
power
is
supplied
on
the
cable
from
residence.
2.
Follow
instructions
on
previous
page
for
Four
Conductor
Wire
Connection
to
Range
(Fig.
7).
3.
Inthe
circuit
breaker,
fuse
box
or
junction
box
(Fig.
9):
a)
Connect
the
white
appliance
cable
wire
to
the
neutral
(white)
wire.
b)
Connect
the
2
black
wires
together.
c)
Connect
the
2
red
wires
together.
d)
Connect
the
green
(or
bare
copper)
grounding
wire
to
the
grounding
wire
of
the
circuit
breaker,
fuse box
or
junction
box.
Cable
from
Residence
Green
(or
Bare
Copper)
Wire
=
White
Wire
Green
(or
Bare
Copper)
Wire
AN
——
White
Wire
Junction
|
Nu
Listed
Conduit
Box
a
Connector
(or
CSA
Cable
from
listed)
Appliance
NOTE:
Be
sure
to
remove
the
supplied
grounding
strap.
————-
Figure
9
4-Wire
Electrical
System
(Example:
Junction
Box)
7.
Checking
Operation
Refer
to
the
Use
and
Care
Guide
for
operation.
Pee
Do
not
touch
cooktop
glass
or
elements.
They
may
be
hot
enough
to
burn
you.
Before
You
Call
for
Service
Read
the
Before
You
Call
for
Service
Checklist
and
operating
instructions
in
your
Use
and
Care
Guide.
lf
may
save
you
time
and
expense.
The
list
includes
common
occurrences
that
are
not
the
result
of
defective
workmanship
or
materials
in
this
appliance.