Installation guide

30"
ELECTRIC
RANGE
INSTALLATION
INSTRUCTIONS
Three
Conductor
Wire
Connection
to
Range
If
local
codes
permit
connection
of
the
frame
grounding
conductor
to
the
neutral
wire
of
the
copper
power
supply
cord
(see
Figure
6):
1.
Remove
the
screws
from
the
access
plate
at
the
lower
right
end
of
the rear
cover
to
expose
range
terminal
connection
block.
2.
Using
the
nuts
supplied
in
the
literature
package,
connect
the
neutral
of
the
copper
power
supply
cord
to
the
center
silver-colored
terminal
of
the
terminal
block,
and
connect
the
other
wires
to
the
outer
terminals.
Match
wires
and
terminals
by
color
(red
wires
connected
to
the
right
terminal,
black
wires
connected
to
the
left
terminal)
(see
figure
6).
3.
Replace
the
terminal
cover
and
replace
the
screws.
Silver
Colored
Terminal
:
Cord
Terminal
Mounting
Block
Plate
_
a“
a
Zs
va
Black
Neutral
Wire
(White
Wire)
Grounding
Strap
1
1/8"
(2.9
cm)
Dia.
Direct
Connection
Hole.
Punch
Out
A
User
Supplied
Strain-relief
Must
Be
Installed
at
This
To
240
V
1
Location.
Receptacle
Knockout
for
1
3/8
(3.5
cm)
Dia.
Cord
Kit
Hole.
Figure
6
Four
Conductor
Wire
Connection
to
Range
Where
local
codes
does
NOT
permit
connection
of
the
frame
grounding conductor
to
the
neutral
wire
of
the
copper
power
supply
cord
(see
Figure
7):
1.
Remove
the
screws
from
the
access
plate
at
the
lower
right
end
of
the rear
cover
to
expose
range
terminal
connection
block.
2.
Remove
the
grounding
strap
from
the
terminal
block
and
from
the
appliance
frame.
3.
Using
the
nuts
supplied
with
the
literature
package,
connect
the
ground
wire
(green)
of
the
copper
power
supply
cord
to
the
frame
of
the
appliance
with
the
ground
screw,
using
the
hole
in
the
frame
where
the
ground
strap
was
removed
(see
Figure
7).
4.
Connect
the
neutral
of
the
copper
power
supply
cord
to
the
center
silver-colored
terminal
of
the
terminal
block,
and
connect
the
other
wires
to
the
outer
terminals.
Match
wires
and
terminals
by
color
(red
wires
connected
to
the
right
terminal,
black
wires
connected
to
the
left
terminal).
5.
Replace
the
terminal
cover
and
replace
the
screws.
Silver
Colored
Terminal Terminal
Block
Black
Wire
1
1/8"
(2.9cm)
{
Dia.
Direct
Connection
Hole.
Punch
Out
Knockout
fo
1
3/8"
(3.5cm)
Dia.
Cord
Kit
Hole.
(White
Wire}
Ground
(Bare
Copper
Wire)
A
User
Suppliee
Strain-relief
Must
Be
Installed
at
This
Location
To
240
V
Receptacle
NOTE:
Be
sure
to
remove
the
supplied
grounding
strap.
-——
Figure
7