4.BuildawoodenframewiththeINSIDEdimensionsofyourmodellistedabove.(Measuretwiceremember...)Frame
depthshouldbethesameaswallthickness.Fillinthespacefromtheopendingtothestudswithwoodspacers,as
shown.
5.Nailframetospacerstospacerswithfrontflushwithdrywall.
Ifwallthicknessis8-1/2"ormore,addalumimumflashingoverbottomofframeopeningtoassurenowatercan
enterareabetweeninnerandouterwall.
NAiLSPACERS
i! i TOSTUDS
,,,, :::: F,G.4
ALUMINUM FLASHING
OVER BOTTOM OF FRAME
_ Prepare and install Cabinet
t. Slide air conditioner from cabinet; refer back to Step 1 of Window Mounting.
2. Place cabinet into opening with bottom rail resting firmly on bottom board of wooden frame.
3. Position cabinet to achieve proper downward tilt for water removal. Unit must tilt back about 7/8" to 1 1/4" for proper
water drainage. (See FIG.5 below.)
4. Secure bottom rail to wood frame with two large wood screws 1" (2.5 cm) long using the two holes in the bottom of
the channel resting on frame. (See FIG.6 following)
FIG.5
F-q
FIG.6
, _ about 7/8"- 1 1/4"
I' I"LONG
WOOD SCREW
Side Louvers
Refer to Step 5 of Window Mounting for assembly of support brackets. Nail a wooden strip to the outside wall for the
angle sill bracket to rest upon. See Fig. 7.
5. Screw or nail cabinet to wooden frame using shims as needed to eliminate cabinet distortion. See Fig. 8. Remember
to maintain proper tilt as described in Step 3.