Combination Frigidaire Gas Cooktop/ 27" Electric
Side-Swing Wall Oven Under-Counter Installation
Frigidaire Gallery Model GLEB27Z7H
27" Electric Single Wall Oven (GLEB27Z7H)
Under-Counter Installation Specifications
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz
AC only electrical supply with ground required on separate circuit
fused on both sides of line.
For detailed electrical requirements, refer to model-specific product
page and installation guide on web.
Always consult local and national electric codes.
Minimum 27-1/4" clearance for oven door depth when open.
Minimum 23-1/2" deep cutout dimension is critical for proper
installation, to ensure that oven’s faceplate will fit flush against
cabinet front.
Minimum 4-1/2" distance required from door hinge side of oven’s
cutout opening to any adjoining cabinetry or wall, to allow sufficient
clearance for oven rack removal.
Side filler panels necessary to isolate oven from adjoining cabinets.
Oven base of solid plywood or similar material required, capable of
supporting 150 Lbs. Install over two runners and flush with toe plate.
Base must be level and cabinet front must be square.
Recommended that bottom of cabinet remain partially opened to
permit free air circulation, avoiding possible water condensation
which may appear inside control panel while operating oven.
Allow 5" maximum height from oven base to floor, if NO cooktop is
installed directly over wall oven.
Gas Cooktop Installation Over
27" Electric Single Wall Oven (GLEB27Z7H) Specifications
Frigidaire® Single Wall Oven model GLEB27Z7H is approved to be used
beneath any approved Frigidaire® Gas Cooktop.
For detailed Gas Cooktop installation, refer to model-specific product
page and installation guide on web.
Side filler panel height may need to be modified to accommodate the
depth of approved gas cooktop models.
Minimum height opening of 6-1/2" (from top of counter) required in
right side filler panel to route gas and electric hookups.
Allow 4-1/2" maximum height from oven base to floor, if cooktop is
installed directly over wall oven.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Gas Cooktop Installation
Over 27" Electric Single Wall Oven (GLEB27Z7H)