Installation guide

Installation
Instructions
Thru-The-Wall
Installation
fy
NOTE:
@
Consult
local
building
codes
prior
to
installation,
or
a
qualified
carpenter.
4
|
Select
Wall
Location
This
air
conditioner
slides
out
from
its
cabinet,
so
that
it
can
be
installed
through
an
outside
wall
as
explained
below.
Heavy
duty
Medium
Max
wall
thickness
10"
8"
fy
NOTE:
e
IMPORTANT:
Side
louvers
must
never
be
blocked.
e
All
parts
needed
for
Thru-The-Wall
Installation
are
provided,
except
a
wood
frame,
shims,
and
10
wood
screws
(#10-1"
long
minimum).
Select
a
wall
surface
that:
1.
Does
not
support
major
structural
loads
such
as
the
frame
construction
at
ends
of
windows,
and
under
truss-bearing
points,
etc.
Does
not
have
plumbing
or
wiring
inside.
3.
Is
near
existing
electrical
outlets,
or
where
another
outlet
can
be
installed.
4.
Faces
to
the
area
to
be
cooled,
and
it
is
not
blocked.
5.
Allows
unblocked
airflow
from
rear
sides
and
end
(outside)
of
installed
air
conditioner.
B
Prepare
Wall
Prepare
wall
in
frame
construction
(including
brick
and
stucco
veneer).
Working
from
inside
the
room,
find
wall
stud
nearect
the
center
of
area
where
air
conditioner
will
be
installed
(by
sounding
wall,
or
by
magnetically
finding
nails).
2.
Cut
out
a
hole
on
each
side
of
center
stud.
3.
Measure
between
inside
edges
of
every
other
stud
as
shown
in
FIG.1.
Carefully
measure
and
cut
an
opening
with
the
following
dimensions
depending
on
your
model.
See
FIG.1
and
FIG.2.
WIDTH
“xX”
=
inside
model
width
plus
twice
the
thickness
of
framing
material
used.
HEIGHT
“Y”
=
inside
model
height
plus
twice
the
thickness
of
framing
material
used.
N
Heavy
Duty
Medium
Capacity:
22,000~28,500BTU
15,000~18,
500BTU
Inside
Frame
Height: 18-7/8"
(47.9
cm)
18”
(45.7
cm)
Inside
Frame
Width:
26-3/4"
(67.9
cm)
23-7/8"
(60.6
cm)
FiIG.A
FIG.2
3-3/8"
MIN
(8.6
cm)
UP
TO
8-1/2"