7.
.
Install the front panel by placing the top of the
panel onto the brackets at the top of the chas-
sis. Rotate the bottom into place while locating
the service cord (or conduit) in a notch at the
bottom or sides of the front panel.
Secure the panel to the chassis with two #10 x
3/4" screws (provided). Attach the bottom
return air louver to the front panel, the louver
snaps into place. The louver can be secured in
place with two #10 x 3/4" screws, provided
(optional).
The filter is already installed in tracks in the
plastic cover.
® Place on
brackets
here
Two
each side of front
!
Louver Screw 9 _ Front Panel
Screw
®
g.
NOTE: If the unit is mounted flush to the floor,
the service cord MUST be rerouted through the
side of the front panel closest to the receptacle.
A notch MUST be made in the front panel side
where the cord exits the unit. It is the responsibility
of the installer to create an exit notch. See diagram
(right) for suggested opening size and placement.
Plug the cord (if applicable) into the appropriate
receptacle. Extra cord may be coiled inside the
front panel behind the return air louver. Restore
power to the unit.
®
5/8" (16mm
Not to
scale
.... 711