Manual
Appendix B: Installation of
Central Desk Control
Follow steps 1 through 5 (pages 4 and 5), then:
®
6. Attach two wires from the central desk control to the
terminal board on the right side of the control box.The
central desk control must provide 24 volts AC to this
terminal board in order to switch the unit to the unoc-
cupied mode. When the 24 volts AC is turned off, the
unit returns to the occupied mode.
7.
8.
g.
If filter is not in place, locate and place as shown.
Install the front panel by placing the top of the panel
onto the brackets at top of the chassis. Rotate the
bottom into place while locating the service cord
(or conduit) in the notch at the bottom or sides of
the front panel.
Secure the panel to the chassis with two #10 x
3/4" screws (provided). Attach the bottom return
air louver to the front panel. The louver can be se-
cured in place with two #10 x 3/4" screws provided
(optional).
®
Place on
brackets
here.
(_ Filter
I
f. ....
Front Panel
(not in place yet)
m
_ Evaporator Coil
In//
....,1_- _ Thermostat Bulb
NOTE: Two screws are in
each side of front panel.
Louver Screw _ I
Front Panel
Screw
r