9 FRIED RICH Model PDXDAA & PDXDEA Installation Instructions Lateral Duct Accessory Kit For Use with F Series Packaged Terminal Air Conditioner or Heat Pump Introduction: These instructions cover the installation of the Lateral Duct Accessory Kit for Packaged Terminal Air Conditioner (PACT) units. Please read these instructions completely before attempting installation.
9 FRIED RICH Model PDXDAA & PDXDEA = 4. Secure bracket (be sure to use correct bracket Installation as there is a left and right bracket) with 3 screws provided. Do not over tighten. See Fig. 4. Figure 4 — Support Bracket Attached to Wall Sleeve Electrical Shock Hazard Disconnect all electrical i power to unit before service a Le or Installation. Allure to do $0 can result in property damage, personal Injury and/or death. fd CROTCHET Mount Support Brackets to Wall Sleeve 1.
9 FRIED RICH Model PDXDAA & PDXDEA 9. Remove and discard discharge grille by removing attachment screws from inside of front panel. See Fig 6. Figure 6 — Back View of Front Panel HABER Se Ee ALK Optional — for easy access to control panel, remove the control door by removing the hinges pins from inside of front pane! that secure control door in place. Replaces the front panel. Install Extension Duct (Use for Left or Right Applications) 10. Temporarily secure plenum to support brackets previously installed.
9 FRIED RICH Model PDXDAA & PDXDEA NOTE: The final length of duct may be cut short of outside of wall opening as the Wall Register inner flange will cover this 4 in. gap. This is to allow for flush mounting of the Wall Register to the wall. 16. Trim the Extension Duct interior insulation back approximately allow installation of wall register. See Fig 9. Figure 9 — Trimmed Insulation in Extension Duct RAT HI CHIME Hig, EAGER 17.
9 FRIED RICH Model PDXDAA & PDXDEA Install Wall Register 20. In adjacent room center the register on the duct end and push into the duct until the frame is tight to the wall. NOTE: The clips on the register are designed to hold it in place. Adjust Volume of Airflow Between Rooms NOTE: The plenum is factory set for maximum discharge of airflow from front of unit. To adjust the airflow between 2 rooms, adjust the internal baffle as follows: 21. Remove plenum discharge grille. 22.