Submittal Sheet

Ductless_Wall-mounted_Single_Zone_Cool_Only_Submittal_2018
Refrigeration line sets*
USED WITH Length Ft. Liquid Suction Kit#
9000 and 12000
BTU units
15 1/4” 3/8” T32150
35’ 1/4” 3/8” T32350
18000 BTU indoor units
15 1/4” 1/2” T42150
35’ 1/4” 1/2” T42350
24000,30000 and 36000
BTU indoor units
15 3/8” 5/8” T53150
35’ 3/8” 5/8” T53350
WIRED
CONTROLLER
DWC1
Optional Thermostat
WIND BAFFLE USED WITH
DLAWB1 9000 - 12000 Btu wall-mounted single
zone models
DLAWB2 18000 - 36000 Btu wall-mounted single
zone models
Low ambient wind baffle kit
Works with all Friedrich models
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .115 per kWh. For more information, visit www.ftc.
gov/energy. Due to continuing research in new energy-saving technology, specications are subject to change without notice.
*Insulated line sets are available for all Friedrich split systems in 15 ft. and 35 ft. lengths. Each line set is equipped with are nuts on both ends. Both liquid and suction
lines are insulated. Line sets can be joined together with eld supplied double male connectors. Each system requires one line set for each indoor unit installed. On
multi-zone systems, line sets should be ordered based on individual indoor unit capacities not total system capacity.
PERFORMANCE RATINGS Single Zone Wall-Mounted - Cool Only
9k 12k 18k
SYSTEM MODEL NO.
M09CJ M12CJ M18CJ*
INDOOR MODEL MW09C1J MW12C1J MW18C3J*
OUTDOOR MODEL MR09C1J MR12C1J MR18C3J*
SPECIFICATIONS
CAPACITY COOLING (RATED) Btu 9,000 10,600 17,000
CAPACITY COOLING (MIN~MAX) Btu 3,070~12,120 3,070~13,660 3,070~20,470
COOLING AMPS 6 7.3 6.3
SENSIBLE HEAT RATIO .71 .71 .72
SEER 21.5 21.5 18.0
EER 13.3 13.0 12.0
ENERGY STAR YES YES NO
MOISTURE REMOVAL Pts/h 2.3 2.7 4.2
AIRFLOW (QUIET, LOW, MED, HIGH) CFM 124/212/272/335 124/212/272/335 300/371/441/512
SOUND RATING - INDOOR dB-A 19 / 24 / 33 / 38 19 / 24 / 33 / 39 29 / 35 / 40 / 45
SOUND RATING - OUTDOOR dB-A 45 45 53
OPERATING RANGE ( 0°F WITH WIND BAFFLE) °FDB 14(0)~118 14(0)~118 14(0)~118
EST. YEARLY OPERATING COST $ 61 81 127
ELECTRICAL DATA
POWER SOURCE V 115/60/1 115/60/1 208/230/60/1
MINIMUM AMPACITY A 12 12 19
COOLING WATTS W 677 815 1417
MAX. TD FUSE/BREAKER A 20 20 25
POWER AND COMMUNICATION CABLE
No. x AWG
4 x 14 4 x 14 4 x 14
REFRIGERATION SYSTEM
REFRIGERANT R410A R410A R410A
COMPRESSOR TYPE Single Rotary Single Rotary Twin Rotary
CONNECTIONS Flare Flare Flare
LIQUID LINE O.D. in 1/4 1/4 1/4
SUCTION LINE O.D. in 3/8 3/8 1/2
FACTORY PRECHARGE ft 41 41 25
REFRIGERANT CHARGE oz 36 36 48
MIN./MAX. LINE LENGTH ft 7~66 7~66 10~66
MAX. HEIGHT DIFFERENCE ft 33 33 33
DIMENSIONS & WEIGHT
INDOOR UNIT
W X H X D in
35-1/4 x 11-1/4 x 8-5/16 40-5/8 x 12-7/8 x 9-5/8
NET WEIGHT lbs 23 23 32
SHIPPING WEIGHT lbs 27 27 40
OUTDOOR UNIT
W X H X D in
30-5/16 x 21-5/16 x 11-5/16 34-5/16 x 25-7/8 x12-5/8
NET WEIGHT lbs 78 78 97
SHIPPING WEIGHT lbs 79 79 101
TOTAL NET WEIGHT lbs 101 101 129
TOTAL SHIPPING WEIGHT lbs 106 106 169