Manual

28
Instructions for Converting Range to Operate on Liquefied Petroleum Gas
INSTALLATION AND SERVICES MUST BE PERFORMED BY A QUALIFIED INSTALLER
IMPORTANT: SAVE INSTRUCTION MANUAL FOR THE LOCAL INSPECTOR’S USE.
READ AND SAVE THESE
INSTRUCTIONS
FOR FUTURE REFERENCE
This conversion kit must be installed by a qualified service
technician in accordance with the manufacturer's instructions and all applicable
codes and requirements of the authority having jurisdiction. Failure to follow
instructions may result in fire, explosion or production of carbon monoxide causing
property damage, personal injury or loss of life. The qualified service agency is
responsible for the proper installation of this kit. The installation is not proper and
complete until the operation of the converted appliance is checked as specified in
the manufacturer's instructions supplied with this kit.
Before proceeding with the convers
ion, shut off the gas supply
before disconnecting electrical power to the range. Be sure power supplies are off
before installing the conversion kit. Failure to do so could cause serious bodily injury.
Determine the combination of top burners that are featured on your range. Identify
the parts you need from this kit to complete the L.P. conversion. When burners are
converted from natural to L.P. the BTU ratings are as follows:
Top Burner 6,000 BTU L.P. Gas [ 0.74mm ]
Top Burner 9,000 B
TU L.P. Gas [ 0.90mm ]
Top Burner 9,000 BTU L.P. Gas [ 0.90mm ]
Top Burner 12,000 BTU L.P. Gas [ 1.0mm ]
Top Burner 15,000 BTU L.P. Gas [ 1.16mm ]
Top Burner 20,000 BTU L.P. Gas [0.89 +0.53mm]
Broil Burner 10,000 BTU L.P. Gas [0.94mm]
Oven Burner 22,000 BTU L.P. Gas [1.40mm]
Straight Burner 14,000 BTU L.P. Gas [ 1.09mm ]
*Note: For operation at elevations above 2000ft., appliance rating shall be reduced at the rate of 4%
for each 1000 ft. above sea level .
The original orifices are Nature Gas:
Top Burner 6,000 BTU [ 1.07mm ]
Top Burner 9,000 BTU [ 1.36mm ]
Top Burner 12,000 BTU [ 1.57mm ]
Top Burner 15,000 BTU [ 1.79mm ]
Top Burner 20,000 BTU [ 1.36*2+0.73mm ]
Oven Burner 22,000BTU [ 2.13mm ]
Broil Burner 10,000 BTU [1.mm]
Straight Burner 14,000 BTU [ 1.68mm]
Tools Required for L.P. Conversion:
2mm Allen Wrench
3/8 & 1/2 & 5/8” [19mm] Open End Wrench
1/8” Wide Flat Blade Screwdriver
Philips Screwdriver
7mm Nut Driver
1/4 Nut Driver
Adjustable wrench.
IMPORTANT: After replacing the natural gas to LP orifices, be sure to keep the original
factory installed natural gas orifices for future range conversion back to natural gas.