User Guide
www.fmiproducts.com
113111-01K16
INSTALLATION
Continued
-
WARNING: Never connect
For propane/LP units, installer must supply
an external regulator. The external regulator
will reduce incoming gas pressure. You must
reduce incoming gas pressure to between
11" and 14" of water. If you do not reduce
incoming gas pressure, replace regulator
damage could occur. Install external regula-
tor with the vent pointing down as shown in
Figure 21. Pointing the vent down protects it
from freezing rain or sleet.
CAUTION: Use only new,
-
Propane/LP
Supply Tank
External
Regulator
Figure 21- External Regulator with Vent
Pointing Down
Vent
Pointing
Down
Extension Cord
Use extension cord if needed. The cord must
have a three-prong, grounding plug and a
three-hole receptacle. Make sure cord is in good
shape. It must be heavy enough to carry the
current needed. An undersized cord will cause
a drop in line voltage. This will result in loss of
power and overheating. Use a No. 16 AWG cord
for lengths less than 50 feet.
Figure 20 - Installing Blower Bracket
Assembly
3
2
1
Blower Bracket
Assembly
Screw
Wire Harness
Power
Cord
Valve
Cover
Shield
Box Cover
Wire
Harness
Switch Plate
Switch
Clamp Connector
(not included)
Outlet
Receptacle
Blue
Red
Plastic
Wire Strap