Datasheet
How to choose the best test probe for your job?
Measurement
category In brief Examples
CAT IV Three-phase at
utility connection,
any outdoor mains
conductors
• Refers to the “origin of installation,” i.e., where low-voltage
connection is made to utility power
• Electricity meters, primary overcurrent protection equipment
• Outside and service entrance, service drop from pole to
building, run between meter and panel
• Overhead line to detached building, underground line to well
pump
CAT III Three-phase
distribution, including
single-phase
commercial lighting
• Equipment in fixed installations, such as switchgear and
polyphase motors
• Bus and feeder in industrial plants
• Feeders and short branch circuits, distribution panel devices
• Lighting systems in larger buildings
• Appliance outlets with short connections to service entrance
CAT II Single-phase
receptacle connected
loads
• Appliance, portable tools, and other household and similar
loads
• Outlet and long branch circuits
– Outlets at more than 10 meters (30 feet) from CAT III source
– Outlets at more that 20 meters (60 feet) from CAT IV source
IEC 61010 electrical measurement category ratings for test tools
Make sure that your accessory ratings meet or exceed the rating of your measurement environment.
Patch cords
Patch cords connect two test points or two test instruments or accessories together.
TL932 Patch Cords (90 cm)
One pair (red, black) multi-
stacking banana plug patch cords,
90 cm (35.4 in) long.
• Nickel-plated, 4 mm (0.16 in)
banana plugs
• 90 cm long PVC insulated leads
• 30V rms or 60V dc, 15 A
TL930 Patch Cords (60 cm)
One pair (red, black) multi-
stacking banana plug patch cords,
61 cm (24 in) long.
• Nickel-plated, 4 mm (0.16 in)
banana plugs
• 61 cm long PVC insulated leads
• 30V rms or 60 V dc, 15 A
TL935 Patch Cords
(60 cm, 90 cm, 120 cm)
Three sets (red and black pairs) of
multi-stacking banana plug patch
cords in different lengths.
• Nickel-plated, 4 mm (0.16 in)
banana plugs
• 60 cm, 90 cm, and 120 cm
(23.6 in, 35.4 in, and 47.2 in)
long PVC insulated leads
• 30 V rms or 60V dc, 15 A
TL940 Mini-Hook Test
Leads
One pair (red, black) of test leads
with multi-stacking 4 mm banana
plugs and mini-hooks.
• Mini-hooks attach to component
leads up to 1.5 mm diameter
• 90 cm long PVC insulated leads
• 30 V rms or 60 V dc, 3 A
TL950 Mini-Pincer Test Leads
One pair (red, black) of test leads
with multi-stacking 4 mm banana
plugs and mini-pincers.
• Mini-pincers open to 2.3 mm
• 90 cm long PVC insulated leads
• 30 V rms or 60 V dc, 3 A
TL960 Micro-Hook Test Leads
One pair (red, black) of test leads
with multi-stacking 4 mm banana
plugs and micro-hooks.
• Micro-hooks attach to component
leads up to 1 mm diameter
• 90 cm long PVC insulated leads
• 30 V rms or 60 V dc, 3 A
TL970 Hook and Pincer Set
• TL940 Mini-Hook Test Lead Set
• TL950 Mini-Pincer Test Lead Set
• TL960 Micro-Hook Test Lead Set
11
Test leads
For more information, go to www.fluke.com/accessories