User Instructions

Leak Protection Test
Test the frequency of each point below once a month, under normal
conditions.
1. Press the “RESET” button on the power plug. Power to the unit and the
indicator light will turn off while pressed.
2. While the unit and indicator light are both off, press the “TEST” button
3. Press the “RESET” button. Once released, power to the unit and the
indicator light will turn on, and the unit will resume normal working
conditions.
Indicator
light
Test
button
Rest
button
WARNING
1. Check for any leakage if the power switch does not work properly.
2. The leakage protection plug only protects the product connected to the power
supply through the plug. When using other electrical appliances, the product does
not guarantee the leakage protection of other products; similarly, the product does
not replace the basic safety measures of other electrical appliances.
3. Do not ground the live wire directly, test the leakage protection function of the
product plug.