Installation Guide
Table Of Contents
- 1 Safety and warnings
- 2 Components
- 3 Tools
- 4 Appliance and cavity dimensions
- 5 Cabinetry options
- 6 Stainless steel door panel and toe kick dimensions
- 7 Custom door panel and toe kick dimensions
- 8 Custom door panel installation dimensions
- 9 Custom door panel installation template
- 10 Door clearance
- 11 Electrical and plumbing
- 12 Before installation
- 13 Cavity preparation
- 14 Water and power supply connection
- 15 Top trim installation
- 17 Positioning into cabinetry
- 18 Aligning inside cabinetry
- 19 Door panel installation - stainless steel
- 20 Door panel installation - custom
- 21 Fixing to cabinetry
- 22 Water filter installation
- 23 Toe kick installation
- 24 Door and door trims installation
- 25 Cabinet trims installation — [A] Flexible spring clip method
- 26 Cabinet trims installation — [B] Fixed screw method
- 27 Final checklist
- 1 Consignes de sécurité et mises en garde
- 2 Pièces
- 3 Outils
- 4 Dimensions de l’appareil et de la cavité
- 5 Options d’armoires
- 6 Dimensions de panneau de porte et de plinthe en acier inoxydable
- 7 Dimensions de panneau de porte et de plinthe sur mesure
- 8 Dimensions d’installation de panneau de porte sur mesure
- 9 Gabarit D'installation de panneau de porte sur mesure
- 10 Dégagement de la porte
- 11 Raccordement électrique et plomberie
- 12 Avant l’installation
- 13 Préparation de la cavité
- 14 Alimentation en eau et alimentation électrique
- 15 Installation de la garniture supérieure
- 17 Positionnement dans les armoires
- 18 Alignement dans les armoires
- 19 Installation de panneau de porte — En acier inoxydable
- 20 Installation de panneau de porte — Sur mesure
- 21 Fixation aux armoires
- 22 Installation du filtre à eau
- 23 Installation de la plinthe
- 24 Installation des garnitures de porte et tiroir
- 25 Installation des garnitures de bâti — [A] Méthode avec clip de fixation flexible
- 26 Installation des garnitures de bâti — [B] Méthode avec vis fixée
- 27 Liste de vérification
17
Internal box
A
Anti tip
bracket kit
Anti-tip bracket
(1)
Masonry plug
(4)
#10x40
Pan Head
Philips Screw
#10x40
Pan Head
Philips Screw
#10x40 cross-head screw
(4)
Tools
Cross-head screwdriver
Powered driver (optional)
Pencil
IMPORTANT!
The anti-tip bracket and fittings supplied must be fitted to the wall
ofthefinished enclosure to withstand 220lbs (100kg) load.
Ensure that anti-tip bracket is installed correctly to prevent the
appliancetipping forward when door is open.
Ensure the bracket is secured to structural beams or wall studs
nearesttothe center of the alcove.
WARNING!
Read the following before fastening with masonry plugs and/or screws:
Ensure the screws avoid electrical, gas and water conduits.
Ensure lightweight masonry material such as cinder block
andnewconcrete (no curing time) are not used in installation.
Do not use metallic materials that may corrode, stain and/or
damagetheenclosure.
!3CAVITY PREPARATION
Attach anti-tip bracket
1
Project horizontally from the bottom edge of the finished enclosure
towards the center of the back wall.
– For 80" (2134mm) cavity installation—measure 27/16" (62mm)
downward from the projection line (A).
– For 84" (2032mm) cavity installation—measure 67/16" (164mm)
downward from the projection line (B).
This will locate the contact surface between the bracket and appliance.
2
Mark the location for placement of the anti-tip bracket. Place the bracket
so the top edge of the contact surface aligns with the mark (C).
3
Mark the locations of the screw holes on the wall based on the most
central wall stud (D).
4
Drill screw holes to the marked locations.
5
For wooden/plaster board wall installation:
– Fix the bracket to the wall with #10x40 pan head cross-head screws,
and screw tightly (E).
6
For solid wall installation:
– Hammer masonry plugs into the wall until flush.
– Fix the bracket to the wall with #10x40 pan head cross-head screws
(4x), and screw tightly (F).
A
B
Anti-tip
bracket
E
F
C
D
If the minimum 2 3/8"
(60mm) overlap cannot
be achieved, install a
solid spacer to the wall
stud behind the bracket.
IMPORTANT!
When positioning the appliance
in the cabinetry, ensure that the
anti-tip bracket overlaps the
refrigerator by a minimum 2 3/8"
(60mm) for a secure hold.
.
60mm overlap
Anti-tip
bracket
60mm overlap
Spacer
Anti-tip