Gasoline Fume Detection System Single Channel Systems G-1B-R (Black, Round) G-1C-R (Chrome, Round) Dual Channel System G-2B-R (Black, Square) Owner’s Manual & Installation Instructions Read and comply with all instructions, warnings and limitations before installing, servicing or removing this device.
Additional copies of this manual are available at no charge by contacting the manufacturer, distributor or dealer. Fireboy-Xintex reserves the right to change features without notice.
General Information WARNING GASOLINE FUME DETECTORS ARE MEANT TO SERVE AS A SUPPLEMENTAL WARNING SYSTEM. IT IS NOT MEANT TO REPLACE STANDARD SAFETY PRACTICES WHICH SHOULD BE CARRIED OUT AROUND EXPLOSIVE GASES. The G-1B-R, G-1C-R, and G-2B-R Gasoline Fume Detectors are an effective means to monitor gasoline fumes in an engine compartments, leaking fuel tanks, or fumes from un-burnt hydrocarbons emitted from faulty exhaust systems.
Operation of Xintex Gasoline Fume Detector(s) There are 3 LEDs located on the Display Unit for each channel on the system. The Green LED, located at the top, indicates that the system is operational. The Yellow LED, located in the center, indicates that there is a Fault in the system. This is to notify the user to check the connections and wire runs of the sensors. There may be a break in the wiring or a disconnected sensor on that channel.
Part Number 18140, D, 01/26/2017 G2BS-N01-D G1BR-N01-D G1CR-N01-D BLACK – Ground (-) RED – Power (+) FS-X01 CABLE XX’ RED – Power (+) 1.0 Amp Fuse BLACK – Ground (-) FS-X01 CABLE XX’ FS-X01 CABLE XX’ 1.
Installation Installing the Display Unit (G1BR-N01-D/G1CR-N01-D or G2BS-N01-D) The Display Unit should be located at the instrument panel, so that the visible and audible indicators may be easily observed. Drill a 2-1/16” hole to accommodate the G1BR-N01-D/G1CR-N01-D Display Unit. Drill a 2-1/8” hole to accommodate the G2BS-N01-D Display Unit. Insert Display Unit into hole and secure with the provided threaded mounting nut. NOTE DO NOT MAKE ELECTRICAL CONNECTIONS AT THIS TIME.
Installation Continued Electrical Connections (G1BR-N01-D/G1CR-N01-D or G2BS-N01-D) The Display Unit operates on 9-30 VDC. A Red and a Black 16 GA wire are provided for connecting to the power source. Connect the Red wire to Power (+) with an inline 1.0 Amp fuse. Connect the Black wire to Ground (-). NOTE IMPROPER CONNECTIONS WILL DAMAGE THE DISPLAY UNIT AND WILL VOID WARRANTY.
In the Event of an Alarm Immediately have all passengers and crew exit the passenger compartment and vessel if possible. Ventilate the space being monitored. Carefully check all fuel lines and other potential sources of gasoline fume leaks. If leaks are identified, shut off fuel supply and make any necessary repairs. Repairing Xintex Gasoline Fume Detection Components Xintex Gasoline Fume Detection Components are not field serviceable. Components must be returned to the factory for any repairs.
1 Year Limited Warranty This Warranty is in lieu of all other expressed or implied Warranties Seller warrants title, materials, and workmanship on equipment, except components manufactured by others for which the Seller assigns, as permitted, the original manufacturer’s warranty.