Owners Manual
7
COUNTERTOP OVERHANG
The control panel is designed to sit fl ush against the enclosure front wall. If the non-combustible enclosure countertop extends
beyond the front wall, creating a countertop overhang, it must be cut fl ush with the front wall for the width of the control panel or
a gap will be created exposing the forward portions of the left and right side grill fi re walls. See illustrations above.
MODEL SPECIFICATIONS
Important: FOR YOUR SAFETY, you must provide openings in the island enclosure for drainage, replacement air, and
cross-ventilation of any storage area exposed to possible leakage from gas connections, the unit, or propane
bottles. See the ENCLOSURE REQUIREMENTS section for details.
▲
If equipped
* Note: If using an insulating liner, consult liner instructions for counter cut-out dimensions and installation.
†
Includes any substrate at front wall of enclosure (in the area the rear of the control panel is to sit fl ush against). See SUBSTRATE
section on next page.
‡
Only applicable for non-combustible enclosures that have countertops with an overhang (see illustration and section below).
TOP VIEW
Countertop
Lower support
Countertop
overhang
Control panel
NON-COMBUSTIBLE
CABINET CUT-OUT
DIMENSIONS
Fig. 7-1
FRONT VIEW
B
C
D
Extra cut-out
for Power
Hood only!
1-
1
/
4
" x 10"
11"
See next page
for substrate
considerations
Countertop
overhang
X
TOP VIEW
SIDE VIEW
Countertop
overhang
(Control
panel)
(Countertop)
Y
1
/
4
"
Clearance
(Overhang)
X=
7
/8"
Y= Total
Countertop
Overhang
A
Control
panel
Check clearance for
control panel removal
MODEL SPECIFICATIONS TABLE
Table 1
E660i E790i E1060i
Main burner BTU
N/P orifi ce drill size
25,000
x
3
#42/#54
32,000
x
3
#38/#53
28,000
x
4
#40/#53
Back burner BTU
N/P orifi ce drill size
11,000
#53/#63
13,000
#51/#57
11,000
x
2
#53/#63
Smoker drawer burner BTU
N/P orifi ce drill size
3,000
#68/#77
3,000
#68/#77
3,000
#68/#77
Infrared searing burner BTU
▲
N/P orifi ce drill size
24,000
#45/#55
24,000
#45/#55
24,000
#45/#55
Optional Echelon insulating liner model # 3176-50 3186-50 3185-50
Power Supply Rating
120VAC / 1.5A / 60 Hz
Oven Lights Rating
12V / 10 watt halogen light bulb
A Countertop to unit bottom cut-out* 12" 12" 12"
B Side to side non-combustible cut-out* 31-
1
/4" 37" 50"
C Front to back non-combustible cut-out*† 23-
1
/2" 23-
1
/2" 23-
1
/2"
D Control panel width non-combustible cut-out‡ 33" 38-
3
/4" 51-
3
/4"
REV 5 - 1405281125
L-C2-329