Datasheet

56.32/56.34 56.32-0300/56.34-0300
2 CO (DPDT) 4 CO (4PDT)
2NO (DPST-NO) - 1.5mm gap 4NO (4PST-NO) - 1.5mm gap
12/20 12/20
250/400 250/400
3,000 3,000
700 700
0.55 0.55
12/0.5/0.25 12/1/0.5
500 (10/5) 500 (10/5)
AgNi AgNi
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
1.5/1 2/1.3 1.5/— 2/—
(0.8…1.1)U
N
(0.85…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 U
N
/0.6 U
N
0.85 U
N
/—
0.2 U
N
/0.1 U
N
0.2 U
N
/—
20 · 10
6
/50 · 10
6
20 · 10
6
/—
100 · 10
3
100 · 10
3
8/3 10/4 8/4
4545
1,000 2,000
–40…+70 –40…+70
RT I RT I
2 or 4 pole changeover contact
Plug-in/Faston 187
2 or 4 pole normally open contact
(1.5 mm gap)
Plug-in/Faston 187
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Single phase motor rating (230 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (U
N
) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Holding voltage AC/DC
Must drop-out voltage AC/DC
Technical data
Mechanical life AC/DC cycles
Electrical life at rated load AC1 cycles
Operate/release time ms
Insulation between coil and contacts (1.2/50
µ
s)
kV
Dielectric strength between open contacts V AC
Ambient temperature range °C
Environmental protection
Approvals (according to type)
Features
* For 4 CO (4PDT) or 4 NO only.
F
OR UL RATINGS SEE:
“General technical information” page V
1
Plug-in - 12 A Power relay, 2 & 4 pole
Flange mount option -
(Faston 187, 4.8x0.5 mm termination)
AC coils & DC coils
Lockable test button and mechanical flag indicator
Cadmium Free contacts (standard version)
Contact material options
96 series sockets
Coil EMC suppression
Accessories
European Patent
56.32
56.32-0300
56.34-0300
56.34
56 Series - Miniature power relays 12 A
56.32 56.34
56.32-0300 56.34-0300
VII-2012, www.findernet.com

Summary of content (10 pages)