Data Sheet

I-2018www.findernet.com
6
A
60 SERIES
General purpose relays 6 - 10A
60
SERIES
Ordering information
Example: 60 series plug-in relay, 3 CO (3PDT), 12VDC coil, test button and mechanical indicator.
A B C D
6 0 . 1 3 . 9 . 0 1 2 . 0 0 4 0
Series
Type
1 = 8/11 pin plug-in
6 = Faston 187 (4.8x0.8mm)
with flange mount
No. of poles
2 = 2 pole
3 = 3 pole
Coil version
4 = Current sensing (60.12/13 only)
8 = AC (50/60Hz)
9 = DC
Coil voltage
See coil specifications
A: Contact material
0 = Standard
5 = AgNi + Au
B: Contact circuit
0 = CO (nPDT)
2 = Bifurcated contacts
60.12/13 - 6A only
D: Special versions
0 = Standard
C: Options
0 = None
2 = Mechanical indicator
3 = LED (AC)
4 = Lockable test button +
mechanical indicator
5* = Lockable test button + LED (AC)
54* = Lockable test button + LED (AC) +
mechanical indicator
6* = LED + diode (DC, polarity positive
to pin 2)
7* = Lockable test button + LED + diode
(DC, polarity positive to pin 2)
74* = Lockable test button + LED +
diode (DC, polarity positive to pin
2) + mechanical indicator
* Options not available for 220VDC and
400VAC versions.
Selecting features and options: only combinations in the same row are possible.
Preferred selections for best availability are shown in bold.
Type Coil version A B C D
60.12/13
AC 0 0 0 - 2 - 3 - 4 - 5 0
AC 0 0 54 /
AC 5 0 - 2 0 - 2 - 3 - 4 - 5 0
AC 5 0 - 2 54 /
DC 0 0 0 - 2 - 4 - 6 - 7 0
DC 0 0 74 /
DC 5 0 - 2 0 - 2 - 4 - 6 - 7 0
DC 5 0 - 2 74 /
current sensing 0 0 4 0
60.62/63 AC-DC 0 - 5 0 0 0
Descriptions: Options and Special versions
C: Option 3, 5, 54
LED (AC)
C: Option 6, 7, 74
LED + diode (DC, polarity
positive to pin 2)
1
2
3
Lockable test button and mechanical flag indicator (0040, 0050, 0054, 0070, 0074)
The dual-purpose Finder test button can be used in two ways:
Case 1) The plastic pip (located directly above the test button) remains intact. In this case, when the
test button is pushed, the contacts operate. When the test button is released the contacts return to
their former state.
Case 2) The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to
the above function), when the test button is pushed and rotated, the contacts are latched in the
operating state, and remain so until the test button is rotated back to its former position.
In both cases ensure that the test button actuation is swift and decisive.
E
U
R
O
P
E
A
N
E
U
R
O
P
E
A
N
PATENT