T Series Specification

To order Falcon T Series locksets, please consult page 15 for ordering information and assistance.
Indicates interchangeable core available.
Catalog
Number
Function Description
ANSI No.
& Grade
T571
Dormitory Lock
Deadlocking latch bolt by levers except when locked by push button in inside lever.
Key in outside lever locks or unlocks outside lever and releases button. Closing door
releases push button. Inside lever always free.
F90-1
T581
Storeroom Lock
Deadlocking latch bolt by lever inside or key outside. Outside lever is inoperable.
Inside lever always free.
F86-1
T851
Storeroom (Electried – Fail Safe)
Inside Lever Always Free. Latch bolt operated by lever from either side except when
outer lever is electrically locked. When outer lever is locked (inoperable), latch bolt
retracted by key in cylinder outside. 24 volt DC .185 Amps, continuous duty.
T881
Storeroom (Electried – Fail Secure)
Inside Lever Always Free. Deadlocking latch bolt operated by lever inside at all times.
Outside lever inoperable until electrically unlocked, then latch bolt from either side.
When outside lever is inoperable latch bolt retracted by key in cylinder outside. 24
volt DC .185 Amps, continuous duty..
T12
Dummy Trim
Single Trim-surface mounted rigid lever.